REFERENCES
113
5
5.6.2 Overflow
Control
The overflow control parameter can be disabled when decoding codes printed on
small surfaces, which don’t allow the use of an overflow space.
This command does not effect code families 2/5, Code 128 and Code 93.
This command is forced (enabled) when PDF417 codes are enabled.
5.6.3 Interdigit
Control
The interdigit control parameter verifies the interdigit spacing for code families
Code 39 and Codabar.
5.7 CONFIGURATION EDITING COMMANDS
The following commands carry out their specific function and then exit the
configuration environment.
Command Description
iPk
iPk
iPk
Restore TC1100 reader default
configuration (see par. 3.1 for default
settings).
i,k
i,k
i,k
Transmit the TC1100 software release
(not for PEN Emulation)
i@k
i@k
i@k
Transmit TC1100 reader configuration in
readable format (not for PEN Emulation)