TC1100
6
2
RS232 Interface
The TC1100 Scanner can communicate with the Host using the RS232 signals
provided on the 25-pin connector. The pins are indicated in Table 1 and in the
following diagram:
It is always advisable to use shielded cables. The overall maximum cable length
must be less than 15 m (49.2 ft).
TC1100 25-pin
7
4
5
3
SGND
RTS
CTS
RX
TX
2
Host
SGND
DCD
DTR
TXD
RXD
Earth
Ground
Figure 3 - RS232 Interface Connection to Host
WEDGE Interface
The TC1100 Scanner can communicate with the Host in a WEDGE Interface
(Keyboard Emulation) using the signals provided on the 25-pin connector. The pins
are indicated in Table 1 and in the following diagram:
TC1100 25-pin
20
DATAIN
24
CLKOUT
21
DATAOUT
25
GND
VCC+
13
Host
23
CLKIN
Keyboard
GND
VCC+
CLK
DATA
DATA
CLK
GND
VCC+
Figure 4 - Wedge Interface Connection to Host (PC AT) and Keyboard