TC1100
22
3
3.2 TC1100
CONFIGURATION
TC1100 is factory set for RS232 Interface applications. The easiest way to configure
TC1100 is by using the
DL Sm@rtSet™
utility program installed from the CD
included with this manual. Otherwise you can configure the scanner using the serial
string which follow:
To configure TC1100 by using the configuration strings:
1)
Connect your TC1100 to a PC RS232 port according to the information in
chapter 2. Set the PC serial port to the TC1100 default RS232 communication
parameters.
2)
Using a Terminal Emulation Program, send the Restore Default string to the
reader using the syntax described on the next page.
3)
Send all the necessary command strings according to your application's
requirements.
CAUTION
The WEDGE or PEN Emulation interface selections must be sent
last since they will cause the reader to no longer accept RS232
communications.
If working with the Wedge or Pen emulation interfaces, it is possible to return to the
RS232 connection by reading the code given below:
Return to RS232 Interface
i$1k
i$1k
i$1k
For WEDGE or PEN Emulation Users
Summary of Contents for TC1100