Electrical Connections
Led Status
9-pin connector
LED
State
1 VCC
+5
Vdc
ON = Power ON
2 GND
power
ground
POWER
OFF = Power OFF
3 RX
receive
data
ON = Good Read
4 TX
transmit
data
GOOD
OFF = No Read
5 OUT1 +
output 1, positive
ON = External trigger ON
6 OUT 1/2 -
output 1/2 negative
TRIGGER
OFF = External trigger OFF
7 OUT2 +
output 2, positive
8 EXT-TRIG +
external trigger, positive
9 EXT-TRIG -
external trigger, negative
USB Type A connector
1 VCC
+5Vdc
2 DATA-
USB Data, negative
3 DATA+
USB Data, positive
4 GND
power
ground
Physical Dimensions
Model RS232
USB
Width
57 mm (2.24 inches)
Length
50 mm (1.96 inches)
Height
31 mm (1.22 inches)
Weight - max. without cable
120 g. (4.2 oz.)
105 g. (3.7 oz.)
I/O Connections
USER IN TERF ACE
Vext
30 Vdc max
OUT1 +
5
6
OUT1/2 -
TC1200
Example Output 1 NPN Connection
EXT TRIG+
8
9
+ 5V
TC1200
EXTERN AL TR IGGER
Signal
V
30 Vdc max.
Vext
EXT TRIG-
8
9
+ 5V
TC1200
EXTERN AL TR IGGER
30 Vdc max.
Vext
V
Signal
Ground
EXT TRIG+
EXT TRIG-
Input NPN command using external power
Input PNP command using external power
EXTER NAL TRIGGER
TC 1200
Signal
8
9
+ 5V
1
2
GND
Ground
V
EXT TRIG+
EXT TRIG-
Vcc 5Vdc
EXTERNAL TRIGGER
TC1200
8
9
+ 5V
Vcc 5Vdc
1
2
GND
Ground
V
Signal
EXT TRIG+
EXT TR IG-
Input NPN command using TC1200 power
Input PNP command using TC1200 power
External Trigger Connections
Configuration
For detailed information on the TC1200 programmability and complete parameter list,
please refer to the TC1200 Reference Manual available on the website at:
automation.datalogic.com.
Reading Diagrams
The following diagram was obtained according to the conditions listed below. Code reading
with skew angles of less than 10° may cause decreased performance due to direct light
reflection.
Reading Diagram TC1200-1X00
(0,0) corresponds to the scanner output window.
Conditions:
Code = Code 39
Quality = Grade A
Lighting = No Ambient Light (0 Lux)
Pitch = 0°
Skew = 10°
Tilt = 0°
821001860
Distance (mm)
5 mils
20 mils
12 mils
8 mils