VLASE
TM
IR
26
2
14
RESERVED
Digital Input
DO NOT CONNECT
15
RESERVED
Digital Input
DO NOT CONNECT
16
RESERVED
Digital Input
DO NOT CONNECT
17
END
Digital
Output
This signal is used to know if the marking process is
finished (see paragraph 2.4.3.4):
- ON at the end of marking process
18
POWER_ON
Digital
Output
This signal is used to know if the system is already
warmed up: (see paragraph 2.4.3.3)
- ON when the laser is in
STAND_BY
or
READY
state
19
GND
Ground
Ground reference
20
SYSTEM_ALARM
Digital
Output
This signal is used to know if the system is in booting up
state or in error state: (see paragraph 2.4.3.3)
- ON during BOOTING UP
- ON in case of system error
21
GND
Ground
Ground reference
22
ENABLE_OUT
Digital
Output
This signal is used to know if the system is ready to emit
laser radiation: (see paragraph 2.4.3.3)
- ON when the system is in
READY
state
23
SW_READY (*)
Digital
Output
This signal is used to know if a document, sequence or
script is loaded and ready to be executed:
- ON when a document or a sequence is running in
AUTO MODE (**) or WORK MODE (**) (SW_READY
COMPATIBILITY (**) = true)
- ON when a document or a sequence is running in
AUTO MODE (**) and laser in
READY
state
(SW_READY COMPATIBILITY (**) = false)
- ON when a script is running n AUTO MODE (**) and
“IoPort.setReady (true)” function is used
24
GND
Ground
Ground reference
25
GND
Ground
Ground reference
(*) refers to
Lighter user’s manual “Setting I/O parameters” paragraph to set the signal properties
(**) refers to Lighter user’s manual
(***) refer to paragraph 2.5
NOTE:
Connection example in paragraph 2.6.
Summary of Contents for VLASE IR 1PWX-TLS2
Page 1: ...USER S MANUAL VLASETM IR ...
Page 34: ...VLASETM IR 34 2 2 6 CONNECTION EXAMPLES Figure 27 Connection examples ...
Page 85: ...85 EXTERNAL LABEL PLACING Figure 67 Positioning of external labels rack ...
Page 86: ...86 Figure 68 Positioning of external labels resonator ...
Page 90: ...90 BLOCK DIAGRAM VLASETM SAFETY LOGIC DETAILS FOR AUTOMATIC PRODUCTION LINE ...
Page 108: ...108 APPENDIX G MECHANICAL DRAWINGS ...
Page 109: ...109 NOTE Please refer to Datalogic website for detailed drawings ...
Page 112: ......