7.2 MAINTENANCE
The ordinary maintenance program foresees only simple operations. Some operations consist in a mere
“check” of the operating condition.
The maintenance activities must be done in compliance with the legal prescriptions regarding the safety
rules during the operations.
The following parts/functions have to be controlled:
MAINTENANCE PROGRAM
COMPONENT OR FUNCTION
TYPE OF OPERATION
INTERVALS
F-Theta Scan Lens
Check / Clean
Weekly: wipe gently with a dry cloth (
or
soaked in high purity isopropyl alcohol
)
or clean it with air blowing
Rack Air filters
Clean / Replace
Every 3 months (according to the
environment and frequency of use)
7.2.1 F-THETA SCAN LENS CLEANING PROCEDURE
Figure 65: Cleaning F-Theta lens.
WARNING!
Before cleaning the F-Theta scan lens, the marking system MUST be set to SAFE mode:
1- Disable
EXT_ENABLE_A
and
EXT_ENABLE_B
.
2- Disable
INTERLOCK_A
and
INTERLOCK_B
.