DATAMARS

R-IN 1300 MID User Manual – Rev 

3.0

8 (40) 

*sk[_]

Skip time slot on no response: 
*sk0 skip on no response off
*sk1 skip on no response on (default)

*ct[_]

Collision threshold parameter: 
*ct[0 .. 100]  parameter from 0 to 100 (default 33, example *ct33)

*et [_]

Communication selection : 
*et0 Ethernet
*et1 RS232
*et2 RS232 and Ethernet (default)

*br[_]

baud rate: 

*br0 baud rate 9600
*br1 baud rate 19200
*br2 baud rate 38400
*br3 baud rate 57600
*br4 baud rate 115200 (default)

*cl[_]

Code length: 
See Appendix A for more details. 

*cl0 16 characters UIDs (standard, default)
*cl1 15 characters UIDs (Partial code)
*cl2 14 characters UIDs (Partial code)
*cl3 13 characters UIDs (Partial code)
*cl4 12 characters UIDs (Partial code)
*cl5 12 characters UIDs (First character special)
*cl6 11 characters UIDs (Partial code)
*cl7 10 characters UIDs (Partial code)
*cl8 9 characters UIDs (Partial code)
*cl9 8 characters UIDs (Partial code)

Attention: code maybe not unique with the selected code length 

*tt[_]

Tag technology: 

*tt1 tag technology ISO 15693(T-BT1320 T-BT1315) (default)
*tt2 tag technology Philips I-Code I (not available).

Example: 
*tt1:  only ISO
*tt2:  only I-Code I
*tt12: both ISO and I-Code I

*if

Plots  the  current  (TCP/IP)  network  configuration  of  the  reader 
including submask and default gateway 

*ip[_-_-_-_]

Configure the IP (Internet Protocol) number of the reader. 
Example: 
*ip192-168-1-0
Sets the IP number 192.168.1.0
The default IP number of any new reader is 192.168.0.85

*ipsb[_-_-_-_]

Set the IP sub-mask associated to the local IP address: 
Example: 
*ipsb255-255-255-254  set  the  new  sub  mask  for  the  eth0  IP
interface

*ipgw[_-_-_-_]

Set the IP address of the local gateway: 
Example: 
*ipgw192-168-1-201 set the gateway address to 

192.168.1.201

To remove the default gateway: *ipgw0-0-0-0 

*rg[_]

Receiver gain (in case of doubt, do not modify): 
Amplification of the received signal. 

Summary of Contents for R-IN1300 MID

Page 1: ...read TEXTILE ID USER MANUAL Version 3 0 Corporate Headquarters Textile ID business division Via Industria 16 6814 Lamone Switzerland Phone 41 91 935 73 80 Fax 41 91 945 03 30 textile id datamars com www textile datamars com ...

Page 2: ...19 4 10 Inventory Setup 19 4 11 Monitor 20 4 12 Configurations 21 4 13 Firmware Update 21 4 14 USB Setup 22 4 15 Tuning 23 4 16 System Requirements 23 5 USB Usage 24 5 1 USB Serial Emulation 24 5 1 1 First usage 24 5 1 2 Further usage 25 5 1 3 How to discover which COM Port corresponds to the USB Serial Emulation 26 5 2 USB Mass Storage Emulation MID Plus Only 28 6 Tuning 30 7 Technical Specificat...

Page 3: ...ponder are detected HF High Frequency reading is ON Led blinks during software update Antenna Antenna TX RX antenna for example A ST1330TT TTL Interfaces Host Connect to any serial port COM on your PC with RS 232 cable or to any other RS232 Terminal USB USB device port Ethernet Web Server Connect to LAN with a standard Ethernet cable For more info in Ethernet communication please request the R IN1...

Page 4: ...DATAMARS R IN 1300 MID User Manual Rev 3 0 3 40 Power Switch Turn ON and OFF the reader Power Supply Connect the power supply cable 100 240VAC 50 60 Hz o Power Supply Power Switch ...

Page 5: ...r marked Host to any serial port COM on your PC or the reader R IN 1300 MID can be connected to the LAN just like a PC Ethernet cable RJ 45 connectors A direct Ethernet connection between a PC and R IN 1300 MID reader is also possible with an Ethernet Cross Cable supplied together with the reader Refer to Appendix A for more details on how to do this 3 Power Connect the power cable 110 240 V AC an...

Page 6: ...ion is not granted After the reader is turned on for some time the temperature might increase Do not plug unplug any connectors while the reader is turned ON Although R IN1300 MID is protected against ESD to avoid reader malfunction make sure that no direct electrostatic discharge will happen into the reader case antennas or even on metallic parts directly in contact with the reader enclosure or a...

Page 7: ... that the settings are maintained after power off st Store UIDs Usage with the command st switch from the state Store UIDs off to the state Store UIDs on Then start reading with the command d The detected tags are not sent to the output devices but are cumulated internally Using now the command dw the reading process is stopped and the cumulated detected UIDs are sent to the output devices all at ...

Page 8: ...00 range of power from 0 to 4000 mW default 2000 mW Example pw2000 The selected output power is an approximate value dt _ Time between UIDs This parameter inserts a time delay between the transmission of codes dt 0 200 range of time between UIDs from 0 to 200 units default 0 1 unit 10 ms example dt10 100ms lc _ Lock code lc0 lock code disabled default lc1 lock code 1 enabled lc2 lock code 2 enable...

Page 9: ...de cl8 9 characters UIDs Partial code cl9 8 characters UIDs Partial code Attention code maybe not unique with the selected code length tt _ Tag technology tt1 tag technology ISO 15693 T BT1320 T BT1315 default tt2 tag technology Philips I Code I not available Example tt1 only ISO tt2 only I Code I tt12 both ISO and I Code I if Plots the current TCP IP network configuration of the reader including ...

Page 10: ...ex 100 ts _ Time slots ISO 15693 ts0 single time slots ts1 16 times slots default qm _ Quiet mode When this mode is enabled the transponder will answer just once while in the antenna field qm0 quiet mode off default qm1 quiet mode on aw _ Anti collision window correction Range aw 0 32 default 0 Example aw14 NB Customers are not allowed to modify the value of this setting DM Customer Support only r...

Page 11: ...ile The file format per default is CSV so that the journal file can be opened with Microsoft Excel The generic format of journal file looks like this UID0 line separator UID1 line separator UID2 line separator UID3 line separator The customer can configure the line separator and the extension of the journal file Note Refer to chapter 5 2 to get information on how to retrieve and handle the journal...

Page 12: ...R IN 1300 MID User Manual Rev 3 0 11 40 To specify Carriage Return type r To specify New Line type n To specify Horizontal Tab type t fe _ Journal file extension Valid values sequences of characters max length 5 ...

Page 13: ... an Ethernet Cross Cable supplied together with the reader Refer to Appendix A for more details on how to do this In both cases the reader R IN 1300 MID must be provided with a correct IP Address DHCP is not available Thus the reader is not yet able to get its IP address automatically To provide the R IN 1300 MID reader with an IP address it is recommended to configure it with the supplied cross c...

Page 14: ...third party applications can connect to exchange data with configure and monitor the R IN 1300 MID Reader Refer to the R IN 1300 TCP IP Dedicated Protocol UM001031 for a detailed description of the whole communication protocol and syntax 4 3 2 HUMAN INTERFACE The interface graphical program running on the browser shows the configuration of the reader R IN 1300 MID as a tabbed panel Each panel grou...

Page 15: ... to connect while the system is already occupied i e by another user having logged in before gets access in read only mode thus preventing the configuration from being modified at the same time by more users When the user closes the browser the system becomes free allowing other users to login and get read write mode If the currently logged in user forgets to close the browser she he is automatica...

Page 16: ...15 40 Please note in case of problems while connecting to the reader via browser try to clear the cache of the browser 1 First step select Tools and then Internet Options 2 Second step press the button Delete 3 Third step press the button Delete ...

Page 17: ...RL http ip address of the reader forceLogout html and give her his user password 4 6 NETWORK SETUP The Network Setup tab allows users to specify network parameters IP address sub mask and default gateway The IP address can be a fixed IP Address in this case the ip address and port must be specified or a dynamic one DHCP not yet available After having changed any network parameters the browser must...

Page 18: ...hanges done on these fields do not yet affect the system behavior The Remove Header field informs the reader that expected responses must contain only essential information explanations warnings and miscellaneous information must be cut off The Continuous field enables disables the continuous reading mode If this property is enabled inventory cycles are automatically repeated otherwise only one cy...

Page 19: ...and it is detected only once without regard to the time spent in the field A chip having left the magnetic field can be read again only having spent an amount of time T outside of it If the time spent outside the magnetic field is less than T the chip cannot be detected Details for LockCode 3 on counter The transponder is visible only once when entering the magnetic field for the first time Afterw...

Page 20: ... technical purposes only and should NEVER be changed by customers For more information please contact Datamars Support Team 4 10 INVENTORY SETUP The InventoryrSetup tab allows users to specify into more details how the TableTop Antenna works in a non continuous mode set up The Nr of inventories field specifies how many inventories must be done while the Delay between inventories is the time betwee...

Page 21: ...ory cycles The Stop Reader button makes the reader suspend its reading process The Start Monitoring button permits to display the UIDs of the chips found by the reader The Clear Result button clears the UIDs display The Stop Monitoring button stops the display The led D detection is green if the reader sends UIDs red otherwise PLEASE NOTE UIDs are displayed only once duplicated UIDs are not displa...

Page 22: ...rently active configuration select the destination folder using the navigator write the destination file name in the related input field and then press the button Save Configuration To load a previously saved configuration select the folder and file using the navigator and then press the button Load Configuration 4 13 FIRMWARE UPDATE The GUI version running on the browser offers the user a tool to...

Page 23: ...ompted by a pop up window if she he really wants to install and activate it The user can confirm or cancel the operation If the user decides to continue and to activate the new software she he MUST wait until the HF Led in the front panel stops to blink This is the sign to indicate that the installation process is terminated At the end of the installation the reader must be switched off and restar...

Page 24: ...ble CSV or custom Refer to chapter 5 for an exhaustive explanation about installing using and manipulating the USB serial and mass storage emulation 4 15 TUNING This functionality is reserved for technical purposes and it should be needed by qualified technician only For more information refer to chapter 0 4 16 SYSTEM REQUIREMENTS OS MS Windows 98 or higher MAC OS X Linux Software Java 2 Runtime E...

Page 25: ...ON 5 1 1 FIRST USAGE Select the USB Serial functionality with us1 on terminal or via GUI Plug in the USB cable and connect your PC with the R IN1300 USB cable AB The Found New Hardware Wizard window appears automatically Insert the delivered CD Rom into the PC and select Install from a list or specific location Advanced and click Next Select Search the best driver in these locations and Search rem...

Page 26: ...anual Rev 3 0 25 40 Answer Continue Anyway Click Finish 5 1 2 FURTHER USAGE For further usage there is no need to install the USB Serial Drivers Just specify that you intend to use the USB Serial Emulation and plug the USB cable in ...

Page 27: ...DATAMARS R IN 1300 MID User Manual Rev 3 0 26 40 5 1 3 HOW TO DISCOVER WHICH COM PORT CORRESPONDS TO THE USB SERIAL EMULATION Open the control panel Select System ...

Page 28: ...can open a terminal on Gadget Serial ie COM 7 without need to specify baud rate data bits parity bit stop bit and flow control NB If the USB Cable is unplugged the USB Serial Communication stops If now you plug the USB Cable in the USB Serial Communication will NOT start After unplugging you have to close the terminal plug the USB Cable again and open a new terminal ...

Page 29: ...tionality with us2 on terminal or via GUI Start reading the detected UIDs are written into the journal file duplicated UIDs are filtered each UID is written only once Stop reading Plug in the USB cable and connect your PC with the R IN1300 USB cable AB For technical reason wait 4 5 seconds so that the system can prepare the journal file Find the journal file use Explorer ie Drive F R IN1300 journa...

Page 30: ...le procedure from the beginning Please note The USB Cable can be plugged in ONLY when the reader is not reading The journal file in the emulated USB Mass Storage should only be copied to the PC The saved data will be automatically deleted when the reader is turned off The reader must be reset each time at the end of the procedure ...

Page 31: ...NF button The value in the gray box starts to be updated in real time and the coloured box changes its colour in real time green yellow or red according to the estimated noise Please note that during this phase no tag must be in the magnetic field of the antenna To stop the NF measurement press the STOP NF button The average value is computed and depicted in the coloured box Once the noise floor i...

Page 32: ...DATAMARS R IN 1300 MID User Manual Rev 3 0 31 40 The average value is computed and shown in the box below the Stop SNR button ...

Page 33: ...amplitude shift keying ASK and the tag replies by load modulating the data on the carrier Once the reader is connected to an appropriate client network via dedicated computer it works based on the installed software like a server providing the received data from the transponders to the final client application The service software helps to control and update the reader in user friendly way R IN130...

Page 34: ...ndesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a r...

Page 35: ...ically radiated power e i r p not higher than the permitted one for a successful communication Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device 7 3 5 CE CERTIFICATION The system R IN1300 MID is in accordance with the requirements of pro...

Page 36: ...click the entry corresponding to the connection you intend to use to communicate with the reader You will see a similar frame Click the button Properties of the tab General to get access to the Connection Properties frame You will see a similar frame Highlight the Internet Protocol TCP IP and click the Properties button to get access to the Internet Protocol TCP IP Properties frame You will see a ...

Page 37: ...lick the Use the following IP address radio button and specify an IP in the same range of the readers IP i e 192 168 1 1 the subnet mask 255 255 255 0 You can ignore the Default Gateway Leave the configuration tool confirming by clicking the OK button ...

Page 38: ...ers UID 2 cl1 to cl9 The reader returns only the right most digits of the original 16 digit UID With this format it is not possible to guaranty the uniqueness of the codes 3 cl5 The reader returns 12 digits code in the fashion of cl2 but in this case the first left chapter ranges from G to Z instead of from 0 to F With this format it is not possible to guaranty the uniqueness of the codes ...

Page 39: ...ected to the reader Are the transponders you want to read specified in the options Is the HF led on If the three previous points didn t solve the problem turn the reader off wait 10 seconds before turning the reader on again Bad reading or low reading distance Is the antenna near metallic objects or noise source like electric motors Try to move the antenna and the reader away from these objects Th...

Page 40: ...in number Description 1 DC Positive terminal 2 Earth must be connected 3 DC Negative terminal GND Wire section Cable Outer diameter 0 25 0 34 mm2 3 5 5 mm 1 2 DC PLUG TO WIRE CONNECTION The following picture shows how to assemble the connector on the 3 wire cable The 3 wire terminals must be soldered on the connector terminals as described in chapter 1 1 ...

Page 41: ...RS R IN 1300 MID User Manual Rev 3 0 40 40 2 INSTALLATION INSTRUCTION The following figure shows how to connect the RIN1300MID to a 24VDC power supply Note for optimum performance the earth must be connected ...

Reviews: