3.3 Memory
functions
In the ‘memory functions’ menu you will find various features and functions.
The following figure shows the ‘memory functions’ menu:
You can scroll through the ‘memory functions’ by pressing the UP or DOWN button. You can
change the parameter highlighted by pressing the LEFT or RIGHT button
3.3.1 Store in memory
The ‘store in memory’ function enables or disables the function to store ID codes read into the
memory. When this function is OFF, the reader does not record an ID code in the memory.
While it is ON, it stores the data into the memory.
The following figure shows the store in ‘memory function’ enabled:
Thu 07.02.08 14:48:22
85%
PSK
D004811B5E
Type
M:0208
At the moment the
memory contains 208 ID
codes
3.3.2 Memory
hit
The ‘memory hit’ function counts and displays how many times the current ID code read is
present in the memory. When this function is OFF, the reader does not show anything. While it
is ON, it shows the ‘memory hit’ counter on the display.
The following figure shows the memory hit function enabled:
Thu 07.02.08 14:48:22
85%
PSK
D004811B5E
Type
Memory Hit: 3
This ID code has been
found 3 times in the
memory
R-PO7470 Manual – v. 1.1 – August 2008
8