17
If...
This means that...
(6000i-EU, X6i-EU,
406i-EU, 6000-EU,
X6-EU and 406-EU
energizers only)
The warning light is
flashing and a warning
buzzer is sounding…
The energizer has detected a sudden
increase in the load on the fence.
Switch the energizer off, locate and
remedy fault then turn the energizer
on again.
For example, this may occur:
•
if a cutout switch is closed,
connecting a heavily loaded
section of the fence to the
energizer
•
if a branch falls on the fence
•
if the fence or cable connecting
energizer to it experiences a
sudden short to ground
•
if something becomes entangled
in the fence.
(12000i, X12i, 412i,
6000i, 6000i-EU, X6i,
X6i-EU, 406i and
406i-EU energizers only)
The output voltage digits
(large digits on the LCD
display) flash 1.0 kV...
The fence voltage is below 1000 V.
There is a serious fault on the fence
line. See "How do I locate faults?" in
Frequently asked
questions/Troubleshooting
.
(
12000i, X12i, 412i,
6000i, 6000i-EU, X6i,
X6i-EU, 406i and
406i-EU energizers only)
The first red Indicator
light is illuminated
permanently...
The earth monitor voltage is too high.
Use the earth monitoring feature to
monitor the earth. See page 9.
(12000i, X12i, 412i,
6000i, 6000i-EU, X6i,
X6i-EU, 406i and
406i-EU energizers only)
The battery symbol on
the LCD is flashing...
The battery voltage is bad. Check the
battery voltage immediately, using
the battery test setting. See page 10.
If...
This means that...
(12000i, X12i, 412i,
6000i, 6000i-EU, X6i,
X6i-EU, 406i and
406i-EU energizers only)
The right arrow on the
LCD is flashing...
During the first 10 minutes of
operation, the energizer’s remote
control feature can be activated.
During this period, the large arrow on
the LCD display flashes to indicate
this. This occurs each time the
energizer is switched on when the
energizer’s remote control feature
has not been activated This is part of
normal operation.
(12000i, X12i, 412i,
6000i, 6000i-EU, X6i,
X6i-EU, 406i and
406i-EU energizers only)
The energizer is not
pulsing and the last
green Indicator light is
flashing...
The energizer has been switched off
by a remote control handset. If you
think your energizer might be being
controlled by a neighbour’s remote
control handset and you own a
remote control handset yourself,
change your energizer’s address
setting (see the remote control
handset’s user manual). If you do not
have a remote control handset, take
the energizer to an authorised service
centre to have the remote control
feature disabled.
Servicing
This energizer uses Double Insulation, where two systems of
insulation are provided instead of grounding. No equipment
grounding means is provided in the supply cord of a double-
insulated energizer, nor should a means for equipment
grounding be added to the energizer. Servicing a double-
insulated energizer requires extreme care and knowledge of the
system and should only be done by qualified service personnel.
Replacement parts for a double-insulated energizer must be
identical to the parts they replace. A double-insulated
energizer is marked with the words DOUBLE INSULATION or
DOUBLE INSULATED and/or the symbol below.