Extended System-Level Command Functions
Class Series 2 Programmer’s Manual
117
STX KtR Read Data from RFID Tag
(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)
This command instructs the RFID device to read data from the tag and then put that
data into a replaceable field. It is expected that the tag transponder will be within the
read / write distance of the RFID programming device; otherwise, “Void” will be printed
in the text or bar code label field(s).
Syntax:
<STX>KtRUn
1…
n
16
Haaabbbcdee<CR>
Where:
Un
1
…n
16
- (Optional) Where n
1
…n
16
is the Unique Identifier (UID)
in hexadecimal format. Must be sixteen characters
long.
H
- (Optional) Hexadecimal data – “H” may be added
directly after “R” to return a two character hex value of
the data. Since there are two digits per hex value,
replaceable fields should be twice as long than if using
ASCII data (e.g., the character “A” would be returned
as “41”).
aaa
- Starting block number (000
maximum block
number). Transponder dependent.
bbb
- The number of blocks to read (001
maximum block
number). Transponder dependent.
c
- The number of retry attempts, 0-9.
d
- Reserved. Should be 0.
ee
- Field number in which to place the data (must be 01,
02, 03, etc.) matching the order of Label Formatting
command, U.
A 00 value will send tag data to the host with no printing.
Sample:
<STX>L
1911A1802000010TEXT
U
X
<STX>KtRUE00700ABCDEF1234H0000015001
<STX>G
The sample above creates a replaceable text field (01), recalls
data from the RFID tag block zero (reading only one block, which
is attempted nine times), and prints the data in the location
specified by replaceable field.
When using addressed commands and the tag with the specified UID cannot be found, a
standard RFID read/write fault will be issued.
Summary of Contents for A-Class
Page 2: ......
Page 3: ......
Page 5: ......
Page 6: ......
Page 22: ...Overview 8 Class Series 2 Programmer s Manual ...
Page 30: ...Immediate Command Functions 16 Class Series 2 Programmer s Manual ...
Page 138: ...Extended System Level Command Functions 124 Class Series 2 Programmer s Manual ...
Page 160: ...Label Formatting Command Functions 146 Class Series 2 Programmer s Manual ...
Page 180: ...Generating Label Formats 166 Class Series 2 Programmer s Manual ...
Page 192: ...Appendix B Sample Programs 178 Class Series 2 Programmer s Manual ...
Page 200: ...Appendix D Reset Codes 186 Class Series 2 Programmer s Manual ...
Page 212: ...Appendix E Single Byte Symbol Sets 198 Class Series 2 Programmer s Manual ...
Page 264: ...Appendix G Bar Code Details 250 Class Series 2 Programmer s Manual ...
Page 308: ...Appendix Q Plug and Play IDs 294 Class Series 2 Programmer s Manual ...
Page 312: ...Appendix R Line Mode 298 Class Series 2 Programmer s Manual ...
Page 324: ...Appendix T WiFi Region Country Codes 310 Class Series 2 Programmer s Manual ...
Page 334: ......