Example1: The following example encodes a HF tag, starting at block 001, with
“Datamax <CR> writes RFID best.” It includes a Byte Count Specifier (the portion in
bold), where 0024 equals a four-digit decimal data byte count and includes all bytes that
follow until the end of the data. Field termination is set by the byte count.
<STX>L
D11<CR>
2W1X0000000010000
0024
Datamax<CR>
writes RFID best<CR>
E
Example 2: The following format encodes a tag with EPC data “1122334455667788”
with byte count shown in bold. Note that the field data is entered as the hex value for
the ASCII character.
<STX>L
D11
2W1x0000000000000
0008
<0x11><0x22><0x33><0x44><0x55><0x66><0x77><0x88>
E
GEN2 Kill/Access Passwords
Gen2 tags are capable of storing a 4-byte kill password and a 4-byte access password. The
kill password is stored at address 0, word offset 0 and access password is stored at address
0, word offset 2. The default for these passwords is typically 0.
To write these to the tag it is necessary to store the desired password value in the printer
database:
To write the database for the kill password the command is
<STX>KcRIKnnnnnnnn
, where
nnnnnnnn
represents the 4-byte value in hexadecimal pairs; and,
To write the database for the access password the command is
<STX>KcRICnnnnnnnn
,
where
nnnnnnnn
represents the 4-byte value in hexadecimal pairs.
These can also be viewed or modified via the printer’s display under RFID OPTIONS / UHF
SETTINGS. If the stored value for either or both of these passwords is non-zero and a label
formatting command to write EPC data is issued, then these passwords will be written also.
GEN2 Lock States
Gen2 supports a lock state of permalock, pwd-lock or both for any of the data sections of
the tag. This includes access/kill passwords, EPC data, Tag ID or user memory. To store
these states in the printer database the command is
<STX>KcRIGn
, where: 1 is permalock; 2
is pwd-lock; 3 is both; and, 0 is none (default). When a section of the tag is written via
label formatting command and the stored lock state and lock after write are enabled, the
section will be locked.
Summary of Contents for A-Class
Page 2: ......
Page 3: ......
Page 5: ......
Page 6: ......
Page 22: ...Overview 8 Class Series 2 Programmer s Manual ...
Page 30: ...Immediate Command Functions 16 Class Series 2 Programmer s Manual ...
Page 138: ...Extended System Level Command Functions 124 Class Series 2 Programmer s Manual ...
Page 160: ...Label Formatting Command Functions 146 Class Series 2 Programmer s Manual ...
Page 180: ...Generating Label Formats 166 Class Series 2 Programmer s Manual ...
Page 192: ...Appendix B Sample Programs 178 Class Series 2 Programmer s Manual ...
Page 200: ...Appendix D Reset Codes 186 Class Series 2 Programmer s Manual ...
Page 212: ...Appendix E Single Byte Symbol Sets 198 Class Series 2 Programmer s Manual ...
Page 264: ...Appendix G Bar Code Details 250 Class Series 2 Programmer s Manual ...
Page 308: ...Appendix Q Plug and Play IDs 294 Class Series 2 Programmer s Manual ...
Page 312: ...Appendix R Line Mode 298 Class Series 2 Programmer s Manual ...
Page 324: ...Appendix T WiFi Region Country Codes 310 Class Series 2 Programmer s Manual ...
Page 334: ......