44
H-Class
Printer Options (continued)
Menu Item
Details
RFID
Controls the RFID option, where:
If not detected, this selection will result in a
DISABLED message.
RFID MODULE
Sets the mode of RFID operation, where:
DISABLED
Disables the option.
HF
Selects the High Frequency (13.56 MHz) option.
UHF MULTI-PROTOCOL
Selects the Ultra High Frequency (868-956 MHz)
option.
RFID POSITION
Sets the RFID encoding position, where:
(1.10 - 4.00 in.)
1.10
Is the inlay location (as referenced from the leading
edge of the tag moving forward through the printer),
where 0.00 uses the print position to encode tag and
values greater use the present position (subject to
change).
HF SETTINGS
Sets the HF encoding parameters, where:
TAG TYPE
Selects the HF tag type, where:
ISO 15693
TI
PHILIPS
ST LRI512
ST LRI64
Is the type to be encoded.
AFI VALUE
Sets the Application Family Identifier value, where:
(00 – FF)
00
Is the hex value.
AFI LOCK
Locks the Application Family Identifier value, where:
ENABLED
Is write-protected.
DISABLED
Is not protected.
Summary of Contents for H-4212