H-Class
83
Advanced Entry Calibration
Step
Action
Displayed Message
Comment
A
Turn ON the printer.
CANNOT CALIBRATE
-or-
UNCALIBRATED
Wait briefly for
initialization to complete;
see Section 4.1.1.
B
Press ENTER to access
MEDIA SETTINGS. Then
using the UP Button, scroll
to SENSOR CALIBRATION.
MEDIA SETTINGS
ADVANCED MENU must
be enabled to access the
calibration selections.
C
Press ENTER to access
SENSOR CALIBRATION.
Using the DOWN Button,
highlight ADVANCED
ENTRY then press ENTER.
ADVANCED ENTRY
Press EXIT to abort this
procedure.
D
Scroll to TRAN SENSOR
GAIN (or REFL SENSOR
GAIN, if using reflective
media) then press ENTER.
TRAN SENSOR GAIN
yyy (0 - 31)
25
The following examples
detail die-cut media
calibration; however,
unless otherwise noted,
the reflective media
procedure is the same.
E
Install media. Position the
Media Sensor under the
label, then lower and latch
the Printhead Assembly.
TRAN SENSOR GAIN
yyy (0 - 31)
25
See Section 3.2 for
sensor adjustment
instructions.
Do not position the
Media Sensor under a
perforation; and if
using preprinted
media, ensure the
label area placed over
the sensor is free of
text, graphics, lines,
etc.
Summary of Contents for H-4212
Page 1: ...Operator s Manual ...
Page 2: ......
Page 6: ......
Page 16: ...6 H Class ...
Page 40: ...30 H Class ...
Page 86: ...76 H Class ...
Page 142: ...132 H Class ...
Page 146: ...136 H Class ...
Page 150: ...140 H Class ...
Page 158: ...148 H Class ...
Page 162: ...152 H Class ...
Page 176: ...166 H Class ...
Page 180: ......