88
H-Class
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
N
Press the ESC Key.
Use the buttons to scroll
to PAPER SENSOR LEVEL
(or if using reflective
media, REFL PAPER
LEVEL) and then press
ENTER.
Use the buttons to set the
Paper value determined in
Step M and then press
ENTER.
PAPER SENSOR LEVEL
(0 - 255)
173
This is the Paper value.
O
Press the ESC Key.
Scroll to GAP SENSOR
LEVEL (or, if using
reflective media, MARK
SENSOR LEVEL) and then
press ENTER.
Set the Gap (or Mark)
value determined in Step
M and then press ENTER.
GAP SENSOR LEVEL
(0 - 255)
042
This is the Gap (or Mark)
value.
P
Press the ESC Key.
Scroll to EMPTY SENSOR
LEVEL and then press
ENTER.
Set the Empty value
determined in Step M and
then press ENTER.
EMPTY SENSOR LEVEL
(0 - 255)
009
This is the Empty value.
Q
Press the EXIT Key and,
when prompted, press
YES at the SAVE
CHANGES prompt.
OFFLINE
The procedure is
finished, the process
almost complete.
Summary of Contents for H-4212
Page 1: ...Operator s Manual ...
Page 2: ......
Page 6: ......
Page 16: ...6 H Class ...
Page 40: ...30 H Class ...
Page 86: ...76 H Class ...
Page 142: ...132 H Class ...
Page 146: ...136 H Class ...
Page 150: ...140 H Class ...
Page 158: ...148 H Class ...
Page 162: ...152 H Class ...
Page 176: ...166 H Class ...
Page 180: ......