GPI/O Port A Overview
Pin
#
Signal
Signal
Direction
[1]
Jumper
Position
Function /
Description
Installed
Printer chassis is used.
1
Ground
JMP
8
Removed
Ground must be supplied.
Installed
P5VDC is used (.5 amp maximum)
[4]
2
+5 VDC
N/A
JMP 9
Removed
+5VDC must be supplied.
3
Start Of Print
[2]
Programmable
[3]
4
Slew Label
Advances media until the signal goes HIGH and
then, if not in continuous mode, positions at the
next available TOF.
5
Toggle / Pause
Pauses the printer when LOW.
6
Reprint
Input
Reprints the last label without changes; If
always LOW, results in non-stop printing.
7
+24 VDC
P24 VDC (1.5 amp maximum)
8
Ground
N/A
N/A N/A
Printer chassis.
9
Ribbon Low
Programmable
[1]
. Signifies a RIBBON LOW
DIAMETER warning condition.
10
Service Required
Evoked by occurrences listed under ‘Fault
Messages.’
[1]
Active LOW.
11
End Of Print
Programmable
[1]
. Signifies the End of Print
(EOP) process.
12
Media Out
Evoked during an Out of Stock condition.
Active LOW.
13
Ribbon Out
Evoked during an Out of Ribbon condition.
Active LOW.
14
Data Ready
Evoked when a label waits to be printed. After
the Start of Print signal is received, printing
begins. (For syncing with the print cycle, the
End Of Print signal indicates print process
completion.) Active LOW.
15
Option Fault
Output
JMP 1
When inactive, outputs will
be pulled up to a voltage
determined by this jumper
setting, where:
Pins 1 – 2 = +5VDC;
Pins 2 – 3 = +24VDC; or,
None = A common
external voltage (not to
30VDC) via
external pull-ups
(providing a 20K ohm
feedback path through
any two outputs).
Evoked during a Linear Scanner or RFID fault
condition. Active LOW.
GPI/O Port B Overview
Pin
#
Signal and
Direction
[1]
Jumper
Position
Function /
Description
Installed
P5VDC is used (.5 amp maximum).
[4]
1
+5 VDC
JMP 11
Removed
+5VDC must be supplied.
2
Input 6
N/A
N/A
Programmed input function.
3
Input 3
N/A
N/A
Programmed input function.
Installed: Pins 1 – 2
Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3
Programmed output function pulled-up to +24VDC.
4
Output 6
JMP 7
Removed
Determined by an external source and pull-ups, not 30VDC.
Installed: Pins 1 – 2
Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3
Programmed output function pulled-up to +24VDC.
5
Output 3
JMP 4
Removed
Determined by an external source and pull-ups, not 30VDC.
Installed
Printer chassis is used.
6
Ground
JMP 10
Removed
Ground must be supplied.
7
Input 5
N/A
N/A
Programmed input function.
8
Input 2
N/A
N/A
Programmed input function.
Installed: Pins 1 – 2
Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3
Programmed output function pulled-up to +24VDC.
9
Output 5
JMP 6
Removed
Determined by an external source and pull-ups, not 30VDC.
Installed: Pins 1 – 2
Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3
Programmed output function pulled-up to +24VDC.
10
Output 2
JMP 3
Removed
Determined by an external source and pull-ups, not 30VDC.
11
+24 VDC
N/A
N/A
P24 VDC (1.5 amp maximum).
12
Input 4
N/A
N/A
Programmed input function.
13
Input 1
N/A
N/A
Programmed input function.
Installed: Pins 1 – 2
Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3
Programmed output function pulled-up to +24VDC.
14
Output 4
JMP 5
Removed
Determined by an external source and pull-ups, not 30VDC.
Installed: Pins 1 – 2
Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3
Programmed output function pulled-up to +24VDC.
15
Output 1
JMP 2
Removed
Determined by an external source and pull-ups, not 30VDC.
[1]
Signal directions are given relative to the printer.
[2]
If active with no current print job, “WAITING FOR DATA” will be displayed. Specifying a quantity of 9999 while keeping this signal ON will cause non-stop label printing, except in single label “Imaging Mode”, which will cause the printer to stop between labels.
[3]
For setting details, see
PRINTER OPTIONS / GPIO PORT.
[4]
Drawing more than .5 amps can cause unreliable printer operation.
WARNING:
Failure to properly configure the GPIO Port jumper settings may result in damage to the printer and / or applicator.