5.8 Updating the Boot Loader
Updates for the Boot Loader program can be found at
ftp://ftp.datamaxcorp.com
Before performing an update, identify the printer’s current Boot Loader version by printing a
Configuration Label (see Section 4.3.2) and comparing the installed version to those
available from the FTP site. Download the desired version onto your computer’s hard drive
then follow the steps below to install the Boot Loader program.
If power is lost while UPGRADING SOFTWARE is displayed, the printer will
become non-functional and will require factory programming or a main logic
card.
Boot Loader Update Procedure
Step Displayed Message
Action
Comment(s)
A READY
Using the DOS copy
command (where
‘filename’ is the program
to be loaded and ‘lpt1’ is
the selected interface
port), enter the
following:
copy
filename
lpt1
As an example, this would be
entered as:
copy BOOTXC99_1101.bs lpt1
(Where ‘lpt1’ can differ to
include other ports, as
available.)
As data is received, the Comm
Indicator will appear.
B
UPGRADING
SOFTWARE
The new program is being
stored and verified.
C
BOOTXC99_1101.bs
The printer has reset.
D READY
No action required.
The new application is now
running.
;
If UNCALIBRATED is
displayed, see Section 5.2.
;
If the boot loader update failed, try this alternate procedure:
Press and hold the FEED and CANCEL Keys (see Section 4.1) while turning ON the
printer. After SEND SOFTWARE is displayed, release the keys then re-send the file
as described above.
Summary of Contents for A-Class A-4212
Page 1: ...Operator s Manual ...
Page 2: ......
Page 5: ......
Page 6: ......
Page 8: ......
Page 14: ...vi ...
Page 22: ...8 A Class ...
Page 84: ...70 A Class ...
Page 128: ...114 A Class ...
Page 136: ...122 A Class ...
Page 140: ...126 A Class ...
Page 144: ...130 A Class ...
Page 158: ...144 A Class ...
Page 160: ...146 A Class ...
Page 166: ...152 A Class ...