A-Class
25
3.2 Adjusting the Media Sensor
Position the Media Sensor to detect labels as follows:
1.
Ensure that media is routed through the Media Sensor; see Section 3.1.
Media Sensor
Media Sensor
Adjustment Knob
Eye Mark
Media
Media
2.
Depending on the type of media being used, rotate the Media Sensor Adjustment Knob
until the Eye Mark on the Media Sensor is positioned according to the table below.
Media Sensor Adjustment and Type Required
Media Type
Eye Mark Position
Sensor Type Required
Die-cut
Centered over the label
Notched
Centered over the notch
Gap*
Reflective
Centered over the black mark
Reflective
Continuous
Near the middle of the media
Continuous
* Default setting; see Section 4.2.1.