54
A-Class
VOID RETRY & CONT.
VOID is printed on a faulted label, with reprint
attempts occurring automatically, until the RETRY
COUNT has been exceeded and then that label
will be skipped (discarded) and printing will
continue to the next label in queue.
Linear Scanner or RFID required.
System Settings (continued)
Menu Item
Details
VOID DISTANCE
Sets the distance to print VOID on a faulted label,
where:
(0.10 to 2.00 in.)
0.50
Is the distance, measured from the trailing edge,
which establishes the text size.
VOID will not be printed if insufficient text
space exists or if the fault occurred after
printing completed. Also, the text can be
customized; see the
Class Series 2
Programmer’s Manual
.
RETRY COUNT
Sets the number of printing attempts before
declaring a fault, where:
(0 – 3)
1
Is the count.
Greater than 1 (one) counts are valid only
when Linear Scanner or RFID equipped.
BACKFEED ON CLEAR
Determines positioning after a fault is cleared,
where:
ENABLED
Automatically positions the label.
DISABLED
No label positioning occurs, as the location is
assumed correct.
If reloading, the user must place media at the
SOP position.
SCL FONT BOLD FACTOR
Sets a scalable font boldfacing amount, where:
(1 – 36)
08
Is the setting, based on an incrementing scale
where eight (08) is nominal.
Summary of Contents for A-Class Mark II
Page 1: ...Operator s Manual ...
Page 2: ......
Page 5: ......
Page 20: ...10 A Class Peel Point Dimension See Appendix C for the PE Series printer s dimension Peel Bar ...
Page 80: ...70 A Class ...
Page 113: ...A Class 103 ...
Page 115: ...A Class 105 ...
Page 126: ...116 A Class ...
Page 134: ...124 A Class ...
Page 138: ...128 A Class ...
Page 142: ...132 A Class ...
Page 156: ...146 A Class ...
Page 158: ...148 A Class ...
Page 164: ...154 A Class ...