86
Symptom
Causes
Solutions
Printhead Hot
The printhead too hot or is faulty.
Allow to cool or contact your technical
support representative.
There may be a poor cable connection.
Contact your technical support
representative.
FPGA Hardware
The main controller board may be faulty.
Ensure the latest software update has
been performed.
NV RAM Hardware
The main controller board may be faulty.
Contact your technical support
representative.
PAPER Sensor Blocked
Adhesive, dirt or remnants of a label may
be covering the sensor.
Clean the debris from the sensor.
Perform “Calibrate Sensors”
calibration.
The main controller board may be faulty.
Contact your technical support
representative.
The Top-of-Form sensor failed the
“Calibrate Sensors” calibration due to a
faulty sensor.
Contact your technical support
representative.
Paper Calibration
The wrong Top-of-Form sensor side may
have been selected and not able to read
media characteristics.
Ensure the Top-of-Form has been set
correctly.
The characteristics of the media may not
be sensed by the printer. (Ex. gap, notch,
mark)
Set the paper mode to continuous.
Install different media.
No Top-of-Form Found
The gap or mark was not found.
Ensure the Top-of-Form has been
set correctly.
Install different media.
The label image size exceeded the
maximum of 99 inches.
Check the print mechanism for a paper
jam.
Calibrate the printer for the media
being used.
There may be dirt or debris obstructing the
Top-of-Form sensor.
Clean the debris from the sensors.
Perform “Calibrate Sensors”
calibration.
GPIO Hardware
There may be a poor connection to the
GPIO logic board.
Contact your technical support
representative.
The GPIO logic board may be faulty.
Contact your technical support
representative.
Present Sensor
Hardware
There may be a poor connection.
Perform the Present Sensor test.
The Present Sensor module may be
faulty.
Perform the Present Sensor test.
The Ribbon Version may need to be
upgraded.
Ensure the latest software has been
installed.
There may be a poor connection.
Contact your technical support
representative.
The Ribbon Controller module may be
faulty.
Contact your technical support
representative.