RS232 Communication Interface - General Notes & DIP Switch
Settings
Eight-position dip switch, located to one side of the paper roll, is used to select and set the serial RS232
interface. The printer reads these switches once, on initial power-up. The functions assigned to each
switch are listed in
Table 2.
Proper Baud Rate and protocol settings are required to communicate with a host computer. The standard
factory setting is 19,200 BAUD, 8 DATA BITS, NO PARITY BIT, and one STOP BIT, all switches in
off position.
TABLE 2 - DIP switch settings
Dip Switch
Function
1 & 2
Baud rate
SW1
SW2
Standard Baud rate
38,400
Off
Off
19,200
On
Off
9,600
Off
On
4,800
On
On
3
No. of data bits
SW3
7 Data Bits
on
8 Data bits
Off
4 & 5
Parity bit
SW4
SW5
Serial RS232 mode
No Parity
off
off
Odd Parity
on
off
No Parity
Off
0n
Even Parity
on
on
6 Bluetooth
Communication
SW6
Enable
On
Disable
Off
7
Reserved
SW7
Reserved
8 Communication
Interface
SW8
RS232
Off