background image

 

 
 
  Page 4 

 

 Serial iBootBar  v090212d 

 

 

 

Important Safety Information 

 
When using this product, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and 
injury to persons, including the following: 
 

Disconnect all power cords before servicing! 

 

1.  Read and understand all instructions. 

2.  Follow all warnings in the manual and marked on the product.  

3.  Unplug this product from the wall outlet before cleaning.  Do not use liquid cleaners or aerosol cleaners.  Use a damp cloth for cleaning. 

4.  Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet 
basement, or near a swimming pool. 

5.  Do not place this product on an unstable cart, stand, or table.  The product may fall, causing serious damage to the product. 

6.  Slots and openings in this product and the back or bottom are provided for ventilation to protect it from overheating, these openings must not be 
blocked or covered.  The openings should never be blocked by placing the product on the bed, sofa, rug, or other similar surface.  This product 
should never be placed near or over a radiator or heat register.  This product should not be placed in a built-in installation unless proper ventilation 
is provided. 

7.  This product should be operated only from the type of power source indicated on the marking label.  If you are not sure of the type of power 
supply to your home, consult your dealer or local power company. 

8.  This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin.  This plug will only fit into a grounding type 
power outlet.  This is a safety feature.  If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet.  
Do not defeat the safety purpose of the grounding type plug.  Do not use a 3-to-2 prong adapter at the receptacle; use of this type adapter may 
result in risk of electrical shock and/or damage to this product. 

9.   Do not allow anything to rest on the power cord.  Do not locate this product where the cord will be abused by persons walking on it. 

10.  Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.  

11.  Never push objects of any kind into this product through slots as they may touch dangerous voltage points or short out parts that could result 
in a risk of fire or electrical shock.  Never spill liquid of any kind on the product. 

12.  To reduce the risk of electrical shock, do not disassemble this product, but take it to a qualified serviceman when some service or repair work 
is required.  Opening or removing covers may expose you to dangerous voltages or other risks.  Incorrect re-assembly can cause electric shock 
when the appliance is subsequently used.  

13.  Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: 

a)  When the power supply cord or plug is damaged or frayed. 

b)  If liquid has been spilled into the product. 

c)  If the product has been exposed to rain or water. 

d)  If the product does not operate normally by following the operating instructions.  Adjust only those controls, that are covered by the operating 
instructions because improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to 
restore the product to normal operation. 

e)  If the product has been dropped or has been damaged. 

f)  If the product exhibits a distinct change in performance. 

14.  Avoid using a telephone (other than a cordless type) during an electrical storm.  There may be a remote risk of electric shock from lightning. 

15.  Do not use the telephone to report a gas leak in the vicinity of the leak. 

16.  Do not exceed the maximum output rating of the auxiliary power receptacle. 

 

Summary of Contents for sBB-N15

Page 1: ...via RS 232 serial communications and via contact closure inputs The following models are covered in this document Model Power Feed Total Capacity Outlets sBB N15 NEMA 15 Amp 8 x NEMA 5 15 sBB 2N15 2 x...

Page 2: ......

Page 3: ...Instructions 4 Quick Start 5 General Overview 6 Installation 7 Rack Mounting Serial Port Contact Closure Inputs Power Source Serial Operation 9 Control Input Operation 14 Advanced Operation 15 Specif...

Page 4: ...the grounding type plug Do not use a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to res...

Page 5: ...t status iBootBar get outlets To turn on off outlet 1 iBootBar set outlet 1 off To reboot outlet 2 iBootBar set outlet 2 cycle Outlet Status Indicators Reset Pushbutton Recessed Mains Inlet Power Indi...

Page 6: ...models Models with dual inputs sBB 2N or sBB 2C have two inlets mains Each main feeds four outlets Inlet A supports outlets 1 4 and Inlet B feeds 5 8 Dual power inlet models can be used to support hig...

Page 7: ...outlets using contact closure contact open connections Each connection marked 1 through 8 controls the outlet of the same number The remaining 8 connections are ground and are interchangeable Using a...

Page 8: ...Page 8 Serial iBootBar v090212d Expansion Future Expansion No function in the current Serial iBootBar...

Page 9: ...al applications and can be used on 100V to 240VAC The sBB 2C10 provides two IEC 320 style universal inlets for connecting a detachable power cord Two standard IEC to CEE7 European cord sets are suppli...

Page 10: ...must have rights to the selected outlet User set outlet 1 8 on off cycle Sets the selected outlet to the selected state The user must have rights to the selected outlet User set outlet 1 8 name name S...

Page 11: ...Add user rights to outlets and groups Admin del user username Deletes the selected user from the root iBootBar s user table Admin ren user username newname Renames the selected user in the root iBootB...

Page 12: ...ff during a reboot on off on or on during a cycle off on off User 10 get delay set delay 0 99 Get or set the delay time in seconds When multiple outlets are turned On by a single command this delay co...

Page 13: ...in 120 set console baudrate 2400 4800 9600 19200 38400 57600 115200 The baud rate of the serial port 400 4800 9600 19200 38400 57600 115200 bps Admin 115200 set factory defaults Resets all parameters...

Page 14: ...s or deletes a specific outlet on a specific device from the selected group Admin ren group groupname newname Renames the selected group 20 characters max Admin del group groupname Deletes the selecte...

Page 15: ...y switch or relay closures or open collector relay drivers to connect to the sBB inputs If you have any doubts about proper connections consult Dataprobe Technical support The default control is Input...

Page 16: ...es will be formatted as follows cr lf device name outlet outlet name control type source cr lf Where cr ASCII carriage return lf ASCII line feed character device name User programmed name of the sBB o...

Page 17: ...load the latest version of the firmware and upgrade utility from the Dataprobe website Password Recovery Holding the reset button on the front panel of the iBootBar for 5 seconds or longer will initia...

Page 18: ...I S M sBB 2N20 2 x N20 8 x N15 I S sBB 2N20 M 2 x N20 8 x N15 I S M sBB C10 C14 8 x C13 I S sBB C10 M C14 8 x C13 I S M sBB 2C10 2 x C14 8 x C13 I S sBB 2C10 M 2 x C14 8 x C13 I S M sBB C20 C20 8 x C1...

Page 19: ...ies with Part 15 of the FCC rules Operation of this device is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any interference that m...

Page 20: ...Technical Service at 201 934 5111 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shi...