PAGE 8
UV119UE - DSP 500 : USER MANUAL- v. 4.0
05 - WEIGHED TARE
F
+
0
+
5
ACCESS FROM LEVEL:
pre-set tare
(applicable to pre-pack labels only)
The DSP500 Scale allows setting up to no. 20 tare values to be assigned to PLU for preparing pre-
pack labels. The tare values to be assigned can be weighed by the function described on this page.
Attention
:
Settable tare values are totally 20. Each tare can either be manual or
weighed., as an alternative (therefore there are
NOT
20 20
weighed tares!). When a new values is entered for a tare code already
stored for a previous type of tare, the new value replaces the stored one.
Then press
<ENTER>
to access programming:
0 5 W E I G H E D T A R E
Then press
<ENTER>
to access programming:
0 5 T A R E
C O D E
< 1 ÷ 2 0
>
n n
where:
nn
= code number for tare identification (1 to 20)
Then select the code number for the tare and type it in through the digital keyboard, or by using the
arrow keys
<
←
←
←
←
>
and
<
→
→
→
→
>
to increase or decrease. Press the key
<ENTER>
and store the tare value
as follows:
0 5 T A R E
C O D E
n n
G R A M S
t t t t
w w w w
where:
nn
= code number for tare identification (1 to 20)
tttt
= actual tare
wwww
= weight on platter
Place the container representing the tare on the scale platter. As the key
<ENTER>
is pressed, its
weight shall be stored as tare value.
Summary of Contents for DSP 500
Page 1: ...ELECTRONIC SCALE DSP 500 USER MANUAL v 4 0 UV119UE Doc a Ware 960510...
Page 2: ......
Page 4: ...PAGE ii UV119UE DSP 500 USER MANUAL v 4 0...
Page 6: ...PAGE iv UV119UE DSP 500 USER MANUAL v 4 0...
Page 12: ...PAGE 6 UV119UE DSP 500 USER MANUAL v 4 0...
Page 29: ...PAGE 22 UV119UE DSP 500 USER MANUAL v 4 0...
Page 67: ...PAGE 21 UV119UE DSP 500 USER MANUAL v 4 0...
Page 90: ...UV119UE DSP 500 USER MANUAL v 4 0 PAGE 83...
Page 111: ......
Page 112: ...PAGE 104 UV119UE DSP 500 USER MANUAL v 4 0...
Page 113: ...NEW FEATURES PRE SET TARE FUNCTION SELF SERVICE VERSION...