UV119UE - DSP 500 : USER MANUAL - v. 4.0
PAGE 87
5 -
53 - SERIAL CHANNEL
B
F
+
+
5
3
ACCESS FROM LEVEL:
setting serial channel B parameters
(i.e.: baud rate, parity bits, etc.)
This function is to be used for setting the RS422 optional Serial Interface (channel B), in order to
allow communication with a PC. RS422 Standard allows long-distance interconnections and noise-
free performance as compared with RS232c (channel A).
Attention
:
the data transmission parameters set must match those on the PC
connected, which should also include one RS422 Interface.
After entering this function, press
<ENTER>
for programming the baud rate to be used for data
transmission as follows:
5 2 S E R I A L
C H A N N E L
B
S P E E D
b b b b
B A U D S
where:
bbbb
= number of transmitted bits per second (baud)
By the key
<SEL>
choose one of the following baud rates:
1200
-
2400
-
4800
-
9600
.
Then press the key
<ENTER>
or
<
↓↓↓↓
>
to access programming of data parity, as follows:
5 2 S E R I A L
C H A N N E L
B
P A R I T Y
p
where:
p
= type of parity
ODD
,
EVEN
or
NO
parity can be selected by using
<SEL>
key.
Press
<ENTER>
or
<
↓↓↓↓
>
for programming the no. of data bits.
5 2 S E R I A L
C H A N N E L
B
n
D A T A B I T S
where:
n
= number of data bits
The number of data bits can be selected between
7
and
8
, by pressing
<SEL>
.
Press
<ENTER>
or
<
↓↓↓↓
>
for programming the number of stop bits, as follows:
5 2 S E R I A L
C H A N N E L
B
s
S T O P B I T S
where:
s
= number of stop bits
Summary of Contents for DSP 500
Page 1: ...ELECTRONIC SCALE DSP 500 USER MANUAL v 4 0 UV119UE Doc a Ware 960510...
Page 2: ......
Page 4: ...PAGE ii UV119UE DSP 500 USER MANUAL v 4 0...
Page 6: ...PAGE iv UV119UE DSP 500 USER MANUAL v 4 0...
Page 12: ...PAGE 6 UV119UE DSP 500 USER MANUAL v 4 0...
Page 29: ...PAGE 22 UV119UE DSP 500 USER MANUAL v 4 0...
Page 67: ...PAGE 21 UV119UE DSP 500 USER MANUAL v 4 0...
Page 90: ...UV119UE DSP 500 USER MANUAL v 4 0 PAGE 83...
Page 111: ......
Page 112: ...PAGE 104 UV119UE DSP 500 USER MANUAL v 4 0...
Page 113: ...NEW FEATURES PRE SET TARE FUNCTION SELF SERVICE VERSION...