2-10

Part No. 001-4008-101/102

Unit Type

This radio button selects unit type:

z

Remote - Select this option to designate the unit as a Remote station

z

Master - Select this option to designate the unit as a Master station

Designating a unit as Master or Remote sets a flag in the header identifying Unit Type of originating station. 
This function is used in conjunction with “Data Delivery” when running certain user protocols.

Tx Online Diags

Transmission of online diagnostics may be enabled or disabled for any unit without affecting its ability to 
communicate with other units in a network. At the beginning of each data transmission from a unit,          
diagnostics are delivered locally to the units Setup Port regardless of the Tx Online Diags settings. Where          
continuous data transmissions are required from a Master unit, diagnostics are sent at 20 second intervals.

Diagnostics information includes:

z

Short ID, 

z

Internal case temperature (in Celsius),

z

Battery voltage (in volts),

z

RSSI (in dBm), 

z

Forward Power (in watts), 

z

Reverse Power Indicator, 

z

Remote RSSI

z

Receive quality. 

                                                                                                                                                                   
Network Speed

This field selects the network speed (bit rate) of the RF link between units. The can vary from the COM Port 
baud rate but must be the same for all units in a network:

z

2400 b/s for one-quarter channel models of Integra-TR

z

4800 b/s - selectable for quarter-, half- and full-channel models of Integra-TR and for full-channel models 
of Integra-T

z

9600 b/s - selectable for half- and full-channel models of Integra-TR and for full-channel models of           
Integra-T

z

19200 b/s - selectable for full channel models of Integra-TR only

Extended Preamble

This field extends transmitted synchronization time when the unit is used in a network with repeaters. The 
default is 0 mS and the range is 0 to 100 mS in 5 mS intervals. Add 5 to 10 mS for each Repeater an         
Integra-TR communicates through in a network (dependent on user’s protocol).

Summary of Contents for Integra-TR

Page 1: ...Integra TechnicalManual Version Integra TR S e r v i c e ...

Page 2: ...ent for the fixed data market including SCADA systems for utilities petrochemical waste and fresh water management markets and RF boards for OEM applications in the Radio Frequency Data Capture market PRODUCT WARRANTY The manufacturer s warranty statement for this product is available from Dataradio COR Ltd 299 Johnson Avenue Box 1733 Waseca MN 56093 0833 Phone 507 833 8819 The information in this...

Page 3: ...plex modes and offers full duplex in dual unit configuration Settings and connections for these configurations are given later in this manual 1 2 1 CHARACTERISTICS Integra TR has the following characteristics z Selectable network speeds of 4800 and 9600 b s for half channel units as well as 4800 9600 and 19 200 b s for full channel units 2400 or 4800 b s for quarter channel units z Backward compat...

Page 4: ...must be in accordance with the instructions found in this manual and the National Electrical Code ANSI NFPA 70 Division 2 Hazardous classified Location Incendive Wiring Techniques Mount the unit in an enclosure or assembly Route all interconnecting cables DC power and coaxial through conduit as specified in the National Electrical Code document referenced above For further guidance on installation...

Page 5: ...1 3 Part No 001 4008 101 102 Figure 1 2 Installation Dimensions ...

Page 6: ...e l asseg namento della frequenza Il fornitore di questo dispositivo non e responsabile per l uso non autorizzato O aviso advertir importante no uso restritivo estados de todo o membro do EU e do EFTA Este dispositivo é um transmissor de rádio dos dados de VHF UHF pretendido para o uso indoor e ao ar livre A operação deste dispositivo é sujeita à licença do end user O usuário da extremidade é reco...

Page 7: ... ASSESSMENT PROCEDURE REFERRED TO IN ARTICLE 10 5 AND ANNEX IV DESCRIPTION OF THE PRODUCT Manufacturer Dataradio COR Ltd Address 299 Johnson Avenue Waseca Minnesota United States of America Product Brand name Dataradio Product type model 242 4018 xxx Integra TR VHF Intended use Transmission of data acquisition and control messages in the frequency range 132 174 MHz Type of equipment High Speed Tra...

Page 8: ...1 6 Part No 001 4008 101 102 ...

Page 9: ...279 v1 2 1 EN 60950 February 2000 February 1999 1992 incl A1 1993 A2 1993 A3 1995 A4 1997 and therefore complies with the essential requirements and provisions of the Directive 1999 5 EC of the European Parliament and of the council of 9 march 1999 on Radio equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity and Annex IV Conformity Assessment procedur...

Page 10: ...1 8 Part No 001 4008 101 102 ...

Page 11: ...d declare under our sole responsibility that for the following equipment Description High Speed Transparent Radiomodem Transceiver Series Brand Trademark DATARADIO Model numbers 242 4016 xxx T 96SR VHF 242 4018 xxx Integra TR VHF 242 4046 xxx T 96SR UHF 242 4048 xxx Integra TR UHF manufactured by Company Dataradio COR Ltd Address City 299 Johnson Avenue Waseca Minnesota Country United States of Am...

Page 12: ... is available by contacting your sales representative DRL warranties are included in pdf format on CD versions of DATARADIO technical manuals 1 5 REPLACEMENT PARTS This product is normally not field serviceable except by the replacement of complete units Specialized equipment and training is required to repair logic boards and radio modules Contact Technical Service for information before returnin...

Page 13: ...of warranty are subject to repair service charges NOTE All requests for out of warranty repairs require a purchase order and are subject to credit approval Customers are responsible for shipping charges to and from Dataradio on units out of warranty Return shipping instructions are the responsibility of the customer 1 7 PHYSICAL DESCRIPTION Integra TR consists of a logic PCB which includes modem c...

Page 14: ...ogramming Software 1 10 1 RF PATH AND COMMUNICATIONS RANGE Integra TR is designed for use over distances up to 30 miles 50 km depending on terrain and antenna system To assure reliable communications the RF radio frequency path between stations should be studied by a competent professional who can determine what antennas are required and whether or not a repeater is needed 1 10 2 BASIC CONNECTIONS...

Page 15: ...OINT SYSTEM A simple point to point connection is shown in Figure 1 4 Figure 1 4 Point to Point System In this system the user s equipment DTE may be set up in either a peer to peer or a Master Remote configuration 1 10 5 POINT MULTIPOINT SYSTEM Basic point multipoint systems are shown in Figure 1 5 Figure 1 5 Point Multipoint System Simplex or half duplex If a half duplex radio network is used i ...

Page 16: ...stations from hearing each other s responses For full duplex configuration set the receiving unit Rx Tx Mode to Rx Only using the Field Programming Software Set the transmitting unit mode to Tx Only Figure 1 6 Point Multipoint System Full duplex Figure 1 7 Point Multipoint System Full duplex Repeater remote remote remote Master half duplex Full duplex repeater Duplexer remote remote remote RX TX Y...

Page 17: ...may be used in any of the network types described in the preceding sections Figure 1 9 Landline Tail Circuit Note The line modems should be full duplex units Figure 1 10 DCE Crossover Cable for RTS CTS mode USER DTE 1 2 3 4 5 6 7 8 RX Unit DE 9M TX Unit DE 9M DCD RXD GND TXD GND DSR RTS CTS DCD RXD TXD DTR GND DSR RTS CTS 1 2 5 3 5 6 7 8 DE 9F Y CABLE line modem line modem dedicated line Integra D...

Page 18: ...ems or line drivers may require the use of DOX mode and an alternate pinout for DTR DCD CTS and RTS as shown in Figure 1 11 Figure 1 11 DCE Crossover Cable for DOX Mode 1 2 3 7 5 6 4 8 9 DE 9M 4 3 2 8 5 1 7 DE 9M DCD RXD TXD RTS GND DTR CTS DTR TXD RXD CTS GND DCD RTS ...

Page 19: ... temperature Warm Start Tx 3 55 to 70 msec depending on radio model and temperature Tx Turnon Time 4 15 ms typical Rx Tx Bandwidth without tuning 18 MHz 132 150 24 MHz 150 174 16 MHz except 20 MHz 450 470 32 MHz Nominal Dimensions 4 5 W x 2 2 H x 4 75 D 11 4 x 5 6 x 12 1 cm RECEIVER VHF UHF 900 MHz Sensitivity 0 35 µV for 12 dB SINAD Selectivity 25 kHz 75 dB typical 70 dB minimum 72 dB typical 65 ...

Page 20: ...Setup Diag Port Data Format Proprietary binary for setup ASCII for diagnostics Data Rate 9600 b s 8 bit no parity 1 stop bit Analog Inputs Interface Two inputs 0 10 VDC 8 bits May be read only via offline diagnostics Absolute maximum input voltage 20 Vdc Inputs are reverse voltage protected Display 4 Bi color status LEDs RUN PWR CS SYN RX TX RD TD Connectors RF SMA Female COM DE 9F SETUP DIAG DE 9...

Page 21: ...1 Integra TR Front Panel 2 2 1 Antenna Connector Antenna connector is a female 50 ohm SMA type Units operated with a rubber duck antenna connected directly to the antenna connector may exhibit unusual operating characteristics and high levels of reverse power 2 2 2 Connection to DTE Integra TR is configured as DCE Most DTE should be connected using a nine conductor pin to pin straight cable Some R...

Page 22: ...e CS SYN Off No RF RX carrier Green Receive carrier present Red Reserved RX TX Off No RF RX carrier Green Receiving network data Yellow Synthesizer unlocked Red Transmitter is on RD TD Off Idle Green RX data outgoing from RS 232 port Red TX data incoming at RS 232 port Pin Name Function 1 DCD Output Always asserted or asserted when receive RF carrier present selectable via Field Programming Softwa...

Page 23: ...als are described Table 2 4 Table 2 3 Setup Port Signals The Setup port uses a proprietary communications protocol designed to work with the Integra TR Field Programming Software program It is also designed to provide numeric diagnostics information when connected to a PC terminal emulator Pin Name Function 1 DCD Tied directly to DTR 2 RXD Data from Integra TR to setup PC 3 TXD Data from setup PC ...

Page 24: ...e ground with a 3 0 A rating An internal surface mount 3A fuse not field replaceable and a crowbar diode protect the main RF power components from reverse polarity Application of more than 16 VDC will damage the unit and is not covered by the warranty WARNING Do not exceed 16Vdc 2 3 3 Power Analog Connector The 4 pin power analog connector pin out is shown in Figure 2 5 Figure 2 5 Analog Connector...

Page 25: ...ional serial COM Port available 2 4 2 COM Port Settings Integra TR programming is done through the PC s Primary COM Port Primary and secondary COM ports are configured with the Field Programming Software The programming cable included in the Programming Kit DRL part number 250 4008 001 is connected from the Setup Port on the Integra TR to the PC s COM port configured as the Primary Port The Port S...

Page 26: ...t DTR Data Terminal Ready line of the RS232 Port when the port is open for the Primary and Secondary COM Ports Swap COM Ports Selecting the Swap Com Ports button moves the Secondary COM Port settings to the Primary COM Port and moves the Primary COM Port to the Secondary settings Since Integra TR programming is done through the Primary COM Port this is useful when two units are connected to the Pr...

Page 27: ...put to the PC DSR DSR shows the current state of the DSR data set ready line DSR is an input to the PC Table 2 4 Communication Modes Mode Description Sync ESC with No HS Sends data using Sync byte stuffing protocol without handshaking Buffered with No HS Sends buffered data without handshaking Sync Esc with RTS CTS HS Sends data using the Sync Esc byte stuffing protocol with RTS CTS hardware hands...

Page 28: ...cters received since the port was last opened Framing Errors Framing Errors shows the number of Framing Errors received since the port was last opened Dribble Bytes Dribble Bytes shows the number of extra not expected bytes characters received since the port was last opened 2 4 4 Setup Modem Radio Parameters Figure 2 9 Setup Modem Radio Screen The Setup Modem Radio Parameters screen is accessed fr...

Page 29: ...ty This field selects the compatibility mode for use with previous versions of Integras z Integra TR used for networks made up of Integra TR modems z Integra T TR used for on air backward compatibility with the Integra T for bit rates of 4800 and 9600 b s full channel units only The Integra TR is capable of selectable network speeds of 2400 and 4800 b s quarter channel units 4800 and 9600 b s for ...

Page 30: ... intervals Diagnostics information includes z Short ID z Internal case temperature in Celsius z Battery voltage in volts z RSSI in dBm z Forward Power in watts z Reverse Power Indicator z Remote RSSI z Receive quality Network Speed This field selects the network speed bit rate of the RF link between units The can vary from the COM Port baud rate but must be the same for all units in a network z 24...

Page 31: ...ontrol This radio button selects the unit s mode at the beginning of a transmission z RTS Request to Send z DOX Data Operated Transmit Suspend Mode Time Graphic not to scale 100 ms wake up No carrier or data Activity timeout period Carrier sensed no data Suspend mode time Radio on Time Carrier data continues after Activity Timeout Integra TR Radio samples carrier 100ms Radio sees carrier no data s...

Page 32: ...ses the transmitter to turn on Integra Synch Preamble sent The PLC RTU Computer wants to send data CTS sent by Integra after delay 4 Ms Fixed DCD Data Carrier Detect TX data Data is TX d transmitted RTS dropped after last character by PLC etc CTS dropped after last character is on air Character in to char out transit time 37mS Repeater delay 10 preamble Integra TR Control Signal Timing RTS Request...

Page 33: ...odd parity 1 stop 7 bits odd parity 1 stop 8 bits odd parity 2 stop 7 bits odd parity 2 stop 8 bits even parity 1 stop 7 bits even parity 1 stop 8 bits even parity 2 stop 7 bits even parity 2 stop Data Fwd Timer This field selects the timing between data blocks in a transmission to accommodate some RTU s special timing requirements z Normal 15 ms option z Fast 5 mS option do not use for baud rates...

Page 34: ...n hardware configuration and should not be changed in the field Analog 2 This field selects configuration of Pin 4 of the Power Analog connector white wire z Input for use on units not equipped with the cooling option can be used to monitor an external voltage 0 to 10 volts z Rx TP performs as the demodulated signal level test point The Rx TP level is half of the internal Rx Test Point z Ant SW Co...

Page 35: ...shold may be raised to prevent false Carrier Sense operation in the presence of noise inter modulation or other sources of interference i e for ambient noise at 100 dBm set the Carrier Sense for 95 dBm Tx Timeout Tx Timeout is used to set maximum period of time the unit will allow in a transmission The range is 0 to 120 seconds in 1 second intervals 0 being disabled Tx Timeout is used to protect b...

Page 36: ...t Screen 2 4 6 Program Comment ID Figure 2 15 Program Comment ID Screen The Program Comment ID field allows the user to program a Short ID and or Comment This function is used if the Integra TR to be programmed was cloned from another unit See Figure 2 15 Short ID The number 1 to 254 that identifies an individual unit in a network Program Short ID Clicking this button programs the new Short ID Com...

Page 37: ...e status bar at the bottom of the screen The Read Programmable Settings command will read parameters from the current Integra TR and store the information in local memory The parameters can be viewed and or edited with the Setup Modem Radio Parameters screens Note Dataradio recommends a Read be done anytime an initial connection is made to the Integra TR Setup Port before accessing the Setup Modem...

Page 38: ...y to Remote displays the receive quality of the remote unit the number of correctly decoded transmissions received by the remote in the last 15 divided by the number of total transmissions detected by the remote in Link Quality from Remote Link Quality from Remote displays the ratio of data blocks received to data blocks transmitted in Overall Link Quality Overall Link Quality displays the overall...

Page 39: ...emperature internal case temperature in Celsius z Forward Power Forward Power in watts z Reverse Power Reverse Power in watts z Analog Input 1 voltage on the External Analog 1 Input from the Power Analog connector in volts z Analog Input 2 voltage on the External Analog 2 Input from the Power Analog connector in volts z Preamble Good the number of correctly decoded transmissions received in the la...

Page 40: ...nd is sent to the unit connected to the computer if the Local ID button is selected The command is sent to the selected Remote ID if the Remote ID and Selected Remote ID buttons are selected The command is sent to the list of Remote IDs if the Remote ID and Remote ID List buttons are selected Stop The Stop button allows the user to stop any commands for Offline Diagnostics from being sent Save The...

Page 41: ...t to transmit will cause the unit to transmit on the programmed transmit frequency until the Tx Timeout Timer expires Be sure to program the Tx Timeout Timer in the Setup Modem Radio Parameters Screen see Figure 2 9 2 4 11 Online Diagnostics Online Diagnostics are transmitted by each unit in a network before the user s data is transmitted All units must be programmed with the Online Diagnostics pa...

Page 42: ...ys the internal case temperature in Celsius of the unit transmitting the diagnostics Batt Batt displays the supply voltage in volts of the unit transmitting the diagnostics RSSI RSSI displays the RSSI in dBm ID of the unit transmitting the diagnostics This is the RSSI sampled during the last transmission the unit received FwdP FwdP displays the forward power in watts of the unit transmitting the d...

Page 43: ...er to filter Short IDs The following options are available z Off All IDs no IDs are filtered out z ID List only the IDs in the Filter ID List are shown z Selected ID only the selected ID in the Filter ID List is shown Display Display allows the user to format on screen data The following options are available z Scroll by time displays the diagnostics as they are received z Slotted by ID sorts the ...

Page 44: ...er or by pressing the Add ID button ID List Allows the user to select a Short ID from the list to delete A Short ID is deleted from the list by pressing the Delete ID button Alarms Alarms are used with Online Diagnostics When Online Diagnostics are received and a diagnostic field falls outside the Alarm limits a character will designate a value less than the low Alarm and a character will designat...

Page 45: ...larms to the current file Save As The Save As button allows the user to save the current Diagnostic IDs and Alarms to a name different than the current file 2 4 13 User Test Figure 2 21 User Test Screen The User Test utility is an offline function and requires suspension of network operation A User Test s diagnostic parameters include Unit ID The Unit ID is the Short ID of the unit from which the ...

Page 46: ...Total The number of total transmissions detected maximum is 15 Used with Preamble Good this serves as an indication of how well the unit is receiving data RSSI Pwr This panel shows the current RSSI level in dBm while the local unit is receiving and the current power level in watts while the local unit is transmitting Rev Pwr This check box changes forward power to reverse power on the Power Panel ...

Page 47: ...the F6 key will cause the unit to go to receive on the programmed receive frequency 2 4 14 ASCII Hex Terminal Terminal Screens allow the user to select an ASCII or Hexadecimal Terminal Screen for the Primary and Secondary COM Ports configured in the Port Settings screen see Section 2 4 3 Data is sent according to the port configuration set up in the Port Settings screen Figure 2 22 ASCII Terminal ...

Page 48: ...minal screen selects a Hexadecimal Terminal screen to send and receive Hexadecimal data on the Primary COM Port set up in the Port Settings screen Secondary The Secondary Hex Terminal screen selects a Hexadecimal Terminal screen to send and receive Hexadecimal data on the Secondary COM Port set up in the Port Settings screen 2 4 15 Program Code The Program Code pull down menu allows the user to up...

Page 49: ... missed station In this case the response may collide with the next poll further increasing errors Setting an adequate timer margin will avoid problems and maximize performance Avoid flow control Set the Com port baud rate to a value less than or equal to the radio network speed 2400 4800 9600 or 19200 b s In a polling system this will prevent buffer overflow with possible missed transmissions If ...

Page 50: ... The adjustments described below require the following equipment 1 13 3 VDC 5A regulated power supply 2 Radio service monitor IFR1200 or equiv 3 Cable with SMA male connector to connect Integra TR to the service monitor 4 Integra Field Programming Software kit 5 A PC with Windows 95 or later operating system to run the Field Programming Software 6 Normal radio shop tools 3 3 TEST POINT For trouble...

Page 51: ...ltage to 13 3 volts WARNING Do not exceed 16 VDC during setting up for tests and adjustments 3 Using a 9 conductor straight RS 232 cable connect the unit s Setup port to the RS 232 port of a PC and run the Integra Field Programming Software on the PC 4 Press GET for the unit configuration 5 From the Settings menu command click on Radio Settings set the frequency to be used for testing Leave this w...

Page 52: ...ED comes on The CS LED should be off The CS LED should come on within 2 dB from the value set by the Field Pro gramming Software Default approx 105 dBm 110 in non refarmed mode The threshold may be raised to prevent false CS operation in the presence of noise intermodulation or other sources of radio interference e g for ambient noise at 100 dBm measured with a spectrum analyzer set the CS thresho...

Page 53: ... i e Remote Carrier button z Check RF power output from the connected unit by using the Carrier test button The RSSI bar graph will turn to a divided wattmeter Forward and Reflected power z Check carrier frequency from the unit connected by using the Carrier button and a RF communication test set z Check transmit deviation from the unit connected by using TX Tone button and a RF communication test...

Page 54: ...e measure of transmit RF power If power read from Bar graph or from reported diagnostics Note If power read from an external wattmeter Normally 3 5 to 6 0W Normally 4 0 to 5 5W RPWR Approximate measure of reflected power Online Diagnostics Offline Diagnostics 0 if reflected power is within limits 1 if reflected power is too high The threshold is set to approximately 1 4 of FPWR Value is in watts i...

Page 55: ...om 6 0 to 18 8 volts WARNING Do not exceed 16Vdc Application of more than 16 VDC will damage the unit and is not covered by the warranty Should nominally be close to 13 3VDC Operating limits 10 0 to 16 0 V Peak Demodulated signal voltage peak to peak Available only for Offline Get Stats See transmit deviation tables Ext1 User specified Analog 1 input as a voltage be tween 0 and 10 volts DC in tent...

Page 56: ...g test transmissions 4 7 TX TONE The TX Tone is used mainly to check transmit deviation To send a modulated carrier press the TX Tone button see Figure 4 1 z If Source is Local sends a 1200 Hz sine wave for 30 seconds or until the button is pressed again z If Source is Remote causes the selected ID remote to send a tone for 30 seconds Remote transmissions cannot be interrupted All buttons are inac...

Page 57: ...nnected to an Integra TR Quarter Channel Part Number 242 40X8 XXX Native Compatibility Mode Connected to an Integra TR Half Channel Part Number 242 40X8 Y10 Native Compatibility Mode 9600 2 5 1 5 4800 2 5 1 5 Connected to an Integra TR Full Channel Part Number 242 40X8 Y30 Integra T Integra TR Compatibility Mode 9600 3 0 1 5 4800 3 0 1 5 Connected to an Integra TR Quarter Channel Part Number 242 4...

Page 58: ...d Preamble ms 0 Network Speed 19200 Full Channel 9600 Half Channel or 2400 Quarter Channel 9600 Full Channel Tx Time Out 30 sec ON Tx Online Diagnostics Yes Unit Type Master Data Delivery All Suspend Period ms 0 Activity Time out sec 5 Sleep Mode Disable N A COM Port Device Baud 19200 9600 Data fwd timer Normal Parity 8 bit no parity 1 stop bit Break Ignore break Xmit Control DOX DCD Control Activ...

Page 59: ...l 9600 Full Channel Tx Time Out Disable Tx Online Diagnostics Yes Unit Type Master Data Delivery All Suspend Period ms 0 Activity Time out sec 5 Sleep Mode Disable N A COM Port Device Baud 19200 9600 Data fwd timer Normal Parity 8 bit no parity 1 stop bit Break Ignore break Xmit Control DOX Active DCD Control Analog Connector Analog 1 Input Fan Control Input Fan Control Analog 2 RxTp Input RxTp An...

Page 60: ...all 8 CTC 4 in each Z84015 The 64K memory space of the Z84015 is divided into two blocks of 32k each The lower 32K are used for the firmware program and the upper 32K by the CMOS RAM U18 The memory IC used for the program is a CMOS FLASH U22 with 1024 sectors of 128 bytes each The dual Z84015 circuit provides up to 8 Counter Timer Channels CTC 4 Serial Input Output SIO and 32 Parallel In put Outpu...

Page 61: ...CPU SIO A for further processing and conversion to asynchronous format before delivery to the RS 232 driver and to the user port 6 2 5 INTEGRA TR A D AND DIGIPOT An 8 channel 8 bit successive approximation A D converter type ADC0838 U4 is interfaced to CPU U17 and Peripheral U21 CH0 and CH1 are connected to the positive and negative peak detector of the modem section The software can read the posi...

Page 62: ... and will wake up the CPU from Sleep mode after 50 ms When exiting SLEEP mode on a NMI the CPU firmware will increment a counter then return to Sleep until it reaches a limit set by a software parameter When the programmed count is reached the CPU will wake up the radio and the RS232 driver program the synthesizer and watch for channel activity While in sleep mode during the 50 ms pulse an active ...

Page 63: ...OCK RXS SLICER LEVEL RX EN U1B U5D E POT U3A RX GAIN RXA U5C E POT U9D WARP U5B E POT U9B DEV U5A E POT U7B TXA U8A U10 U8B RSSI U1A U1D PEAK DETECT U3C D B U1C FAST PEAK DETECT TX EN TX ENABLE RX EN RX ENABLE SYNTH SYNTHESIZER ENABLE CLOCK DATA RESET U19 X1 19 6MHz CD CARRIER DETECT EXT 1 EXT 2 DIAG U7A TEMPERATURE U6 SENSOR 5 VOLTS U11 U12 REGULATOR SWB 13 6 V OUT F1 REV DESCRIPTION DATE DATARAD...

Page 64: ...all 8 CTC 4 in each Z84015 The 64K memory space of the Z84015 is divided into two blocks of 32k each The lower 32K are used for the firmware program and the upper 32K by the CMOS RAM U18 The memory IC used for the program is a CMOS FLASH U22 with 1024 sectors of 128 bytes each The dual Z84015 circuit provides up to 8 Counter Timer Channels CTC 4 Serial Input Output SIO and 32 Parallel In put Outpu...

Page 65: ...CPU SIO A for further processing and conversion to asynchronous format before delivery to the RS 232 driver and to the user port 6 2 5 INTEGRA TR A D AND DIGIPOT An 8 channel 8 bit successive approximation A D converter type ADC0838 U4 is interfaced to CPU U17 and Peripheral U21 CH0 and CH1 are connected to the positive and negative peak detector of the modem section The software can read the posi...

Page 66: ... and will wake up the CPU from Sleep mode after 50 ms When exiting SLEEP mode on a NMI the CPU firmware will increment a counter then return to Sleep until it reaches a limit set by a software parameter When the programmed count is reached the CPU will wake up the radio and the RS232 driver program the synthesizer and watch for channel activity While in sleep mode during the 50 ms pulse an active ...

Page 67: ...OCK RXS SLICER LEVEL RX EN U1B U5D E POT U3A RX GAIN RXA U5C E POT U9D WARP U5B E POT U9B DEV U5A E POT U7B TXA U8A U10 U8B RSSI U1A U1D PEAK DETECT U3C D B U1C FAST PEAK DETECT TX EN TX ENABLE RX EN RX ENABLE SYNTH SYNTHESIZER ENABLE CLOCK DATA RESET U19 X1 19 6MHz CD CARRIER DETECT EXT 1 EXT 2 DIAG U7A TEMPERATURE U6 SENSOR 5 VOLTS U11 U12 REGULATOR SWB 13 6 V OUT F1 REV DESCRIPTION DATE DATARAD...

Page 68: ...nnel bandwidth equal to 6 25 kHz Network speed This is the bit rate on the RF link between units Could be different from COM port baud rate PLC Programmable Logic Controller An intelligent device that can make decisions gather and report information and control other devices Refarming Strategy for using the radio spectrum more efficiently to meet future communications requirements and the FCC s mi...

Reviews: