120 20191-001
Paragon-III
Technical Manual
17
Table 3 - Checklist A (After installation)
CHECKLIST A
(
Paragon-III
)
Recommended Check out after Installation
Step
ACTION
EXPECTED RESULTS
at 25
°
C
MEASURE WITH
IF NOT?
1
Normal Power-up
Sequence
BDLC-III beeps once, all LEDs come ON for about four seconds, the green
LEDs then flash in a “ripple” pattern for close to two seconds. All LEDs go OFF
except the CK that should flash 6 to 8 times per second.
2
Connect and save unit
config
Press CDip
Get
button
as per CDip Help content
3
Transmitter Output
Power
Press
TXON (Unmod)
5
watts
+0%, -10%
Service monitor set
to read power
or
10W in-line wattme-
ter installed as close
as possible to the
unit antenna con-
nector.
Check for bad connections,
damaged coax cable, etc.
4
Transmitter Reflected
Power
Press
TXON (Unmod)
< 5% of forward power or
as specified by System
Engineering.
10W in-line wattme-
ter
Check for bad connections,
damaged coax cable, etc.
5
RF Link test
Use the mobile address
function and “Send” but-
ton to dynamically test
the link
Look for
“Delivery confirmed” on
the Status bar
Refer to 4.3.1 and to
CDip Help content.
Mobile is out of range
Refer to factory technical
support.