background image

TEACH MODE FUNCTIONS

Push and hold for...

1s

3s

6s

20s

Button release

Function

Idle

Teach1

Teach2

Teach3

Teach6

Idle

Visual Feedback

Green LED on

Green LED off

Green LED on

Green LED off

Green LED on

Green LED on

S3N-PR-X-T53

Idle

Standard Teach (transpa-

rent object)

Teach Translucent Object

L/D Select (Toggle)

Restore factory settings

Idle

T51 SETTINGS

S3N-PR-X-T51-XX

Position the sensor and reflector on opposite sides of the desired 

sensing range. Turn the sensitivity trimmer to maximum. Adjust the 

direction of the sensor in the middle of the angular sensing range. 

To perform this procedure, look at the spot on the reflector from the 

back of the sensor in the direction of the beam, and ensure that the 

spot is entirely contained inside the reflector. Alternatively, find the 

angles where the yellow LED (OUT) is switched ON and OFF in both 

vertical and horizontal directions, and fix the sensor at the center 

between these angles.

Adjust sensitivity to match your application requirements (described 

below for dark on output):

- Turn the sensitivity knob counterclockwise until the sensor turns

ON

- Slowly turn the sensitivity knob clockwise until the sensor turns

OFF

- Fine adjust the sensitivity knob while testing detection to find the 

best compromise for your application: turning counterclockwise

decreases the stability of the detection and increases the transpa-

rent detection capability, and vice versa. For best performance, a

good quality reflector with small prism is recommended (such as

R7). The optimal operation result is obtained when the green LED

turns ON. If you bought a model with DARK/LIGHT adjustment

capability (dual trimmer on user interface), adjust th L/D function to 

match your application requirements.

T53 SETTINGS

S3N-PR-X-T53-XX

Position the sensor and reflector on opposite sides of the desired 

sensing range, and execute the desired Teach Procedure. 

Teach1 (Standard Teach for Transparent Object):

 the sensor 

sets the threshold 8% below the signal measured from the reflector.

Teach 2 (Teach Translucent Object):

 the sensor sets the thre-

shold 12% below the signal measured from the reflector.

Teach 3 (Toggle L/D behavior): 

sensor behavior toggles between 

Light ON and Dark ON modes.

Settings through IO-Link:

 the above teach procedures may also be 

initiated through IO-Link. Furthermore, fine regulation of sensitivity 

can be performed by changing sensitivity parameters.

S3N-PR-X-T5X-XX max. operating distance table (m)

Available Reflectors

R1

R2

R3

R4

R5

R6

R7

2.5

3.5

2.0

TEACH MODE

The selection of the desired teach mode and adjustment of the sen-

sor is performed by pressing the TEACH (T) button and observing the 

green LED behavior; each time the LED toggles a new teach mode 

is selected.

Once a teach mode is selected, it may be confirmed by releasing the 

TEACH button  within 3s from selection. Otherwise, if the TEACH 

button is held for more than 3s after teach mode selection, the teach 

mode is discarded and next one (if available) is selected.

Holding the TEACH button until last available teach mode is discar-

ded will result in factory reset.

In case of error during the teach procedure (e.g. trying to perform 

teach outside the operating range), the yellow LED will flash an error 

status. The error can be canceled by pushing and releasing the teach 

button. The sensor is reverted to the previous status before the error.

TEACH CONTROLS

Teach Button

Teach Button can be used to change the L/D function of the sensor, 

or to execute different teach modes.

U.I Interaction

The green LED toggles to indicate advancement of the procedure to 

next step.

Error Indicator

The yellow LED may flash in the event of a teach error.

©2023 Datasensing S.r.l.
• All rights reserved • Without limiting the rights under copyright,

no part of this documentation may be reproduced, stored in or 

introduced into a retrieval system, or transmitted in any form or by 

any means, or for any purpose, without the express written permission 

of Datasensing S.r.l. • Datasensing and the Datasensing logo are 

trademarks of Datasensing S.r.l.

See 

www.patents.datasensing.com

 for patent list.

This product is covered by one or more of the following patents:
Utility patents: IT102015000057325, IT102017000151097, 
US10823878, US11146425, US11163090.

IO-LINK PARAMETERS

To download the IO-Link parameters, click or scan the QR code below.

S3N-T53

On bag label

WHERE TO FIND YOUR PRODUCT MODEL NAME

S3N-PR-5-T53-OZ

Made in XXXXX     SYYWW

On product

Summary of Contents for S3N-PR T5 Series

Page 1: ...X POLARIZED RETROFLEX FOR TRANSPARENT OBJECTS Safety Precautions Read the precautions for all models at http www datasensing com WARNING This product is not designed or rated to ensure personal safety...

Page 2: ...lector Teach 3 Toggle L D behavior sensor behavior toggles between Light ON and Dark ON modes Settings through IO Link the above teach procedures may also be initiated through IO Link Furthermore fine...

Page 3: ...konzipiert oder ausgelegt Nicht f r solche Zwecke verwenden ACHTUNG Die Nennspannung darf nicht berschritten werden Gefahr von Ausf llen und Br nden WARNUNG Dieses Produkt nicht ber seiner IP Einstufu...

Page 4: ...optimale Leistung wird ein hochwertiger Reflektor mit kleinem Prisma empfohlen z B R7 Das optimale Betriebsergebnis wird erreicht wenn die gr ne LED aufleuchtet Wenn Sie ein Modell mit DUNKEL HELL Ein...

Page 5: ...EMENT Utilisez ce produit dans les limites autoris es par son indice de protection IP et pas au del Autrement vous risquez d endommager des composants AVERTISSEMENT Lesmod lesfonctionnantencourantcont...

Page 6: ...nu lorsque la LED verte s allume Si vous avez achet un mod le dot d une capacit de r glage CLAIR SOMBRE double trimmer sur l interface utilisateur r glez la fonction C S en fonction des exigences de v...

Page 7: ...oppio trimmer Modelli a trimmer singolo Regolazione della sensibilit T51 1 giro LED giallo Stato uscita LED verde T51 Stabilit Regolazione della sensibilit T51 1 giro LED giallo Stato uscita LED verde...

Page 8: ...iflettore In alternativa individuare gli angoli in cui il LED giallo OUT si accende e si spegne in direzione verticale e orizzontale e fissare il sensore al centro tra questi angoli Regolare la sensib...

Page 9: ...0VDC BLUE 3 0V WHITE 2 NPN PNP OUT 2 1 4 3 02 2022 Datasensing S r l Strada S Caterina 235 41122 Modena Italy 39 059 420411 39 059 253973 www datasensing com info datasensing com S3N PR T5X http www d...

Page 10: ...017000151097 US10823878 US11146425 US11163090 T LED LED 3 3 LED LED LED 1s 3s 6s 20s Teach1 Teach2 Teach3 Teach6 LED LED LED LED LED LED S3N PR X T53 S3N PR 5 T53 OZ Made in XXXXX SYYWW IO LINK IO Lin...