SIS-1500 Seafloor Imaging System
5-15
SECTION 5 Maintenance and Troubleshooting
System Troubleshooting
The sonar displays do not
update.
The DSP board in the
workstation is not properly
connected.
Check the wiring to the DSP
board, and then remove and
reinsert the board.
The Synchronizer board in
the workstation is not
functioning.
Check the back panel LED. It
should be flashing at the
repetition rate of the
transmitter. If not, replace the
Synchronizer board.
The Digitizer board in the
sonar electronics is not
functioning.
Replace the Digitizer board if
it has failed.
The sonar displays are
noisy.
The digital multiplexer’s high
voltage power supply is not
turned on.
Verify that the ON/OFF and
HIGH VOLTAGE indicators
on the front panel of the
digital multiplexer are on.
The deck cable or the
armored coaxial cable is
faulty.
Refer to Cable Checks on
page 5-19 and check the
deck cable or the armored
coaxial tow cable.
The shipboard power is noisy
or noise is being coupled onto
the deck cable.
Check the shipboard power
for interfering signals. Also
verify that the deck cable is
not suspended and acting as
an antenna and that the
winch and slip ring assembly
is properly grounded.
If a UPS (Uninterruptable
Power Supply) is being used,
its output may be noisy and is
causing interference.
Disconnect the processor
from the UPS and connect it
directly to a VAC power
source that is not on a UPS. If
the display updates properly,
the UPS is noisy.
If the display still does not
update properly, disconnect
all the external devices from
the processor. If the display
updates properly, then
isolators should be used with
all the external devices, such
as an RS-232 isolator
between the navigation
system and the processor.
Table 5-2 Tow Vehicle Activation Problems
Symptom
Possible Cause
Corrective Action
Summary of Contents for SIS-1500
Page 2: ...ii DATASONICS Volume I System Manual June 1998...
Page 14: ...xiv DATASONICS Volume I System Manual June 1998...
Page 15: ...SIS 1500 Seafloor Imaging System 1 1 SECTION 1 SIS 1500 Overview SECTION 1 SIS 1500 Overview...
Page 16: ...1 2 DATASONICS Volume I System Manual June 1998...
Page 18: ...1 4 DATASONICS Volume I System Manual June 1998 Figure 1 1 SIP 150 Sonar Image Processor...
Page 29: ...SIS 1500 Seafloor Imaging System 2 1 SECTION 2 Specifications SECTION 2 Specifications...
Page 30: ...2 2 DATASONICS Volume I System Manual June 1998...
Page 36: ...2 8 DATASONICS Volume I System Manual June 1998...
Page 38: ...3 2 DATASONICS Volume I System Manual June 1998...
Page 68: ...3 32 DATASONICS Volume I System Manual June 1998...
Page 70: ...4 2 DATASONICS Volume I System Manual June 1998...
Page 84: ...5 2 DATASONICS Volume I System Manual June 1998...
Page 106: ...5 24 DATASONICS Volume I System Manual June 1998...
Page 107: ...SIS 1500 Seafloor Imaging System 6 1 SECTION 6 Drawings SECTION 6 Drawings...
Page 108: ...6 2 DATASONICS Volume I System Manual June 1998...
Page 110: ...6 4 DATASONICS Volume I System Manual June 1998...