DT-6XXX IP-SPOOL Application User’s Manual – Build 12.0
04/13/06
Datatek Applications Inc.
18
on the control page for the individual device. Each string is a single word with no quotes
and can be up to 30 characters long.
The
capture
parameter is used to define the time period between the initial arrival of data
on the virtual printer interface and the time a connection is made to the shared printer. Use
of the capture period minimizes “thrashing” for devices that have irregular printing patterns.
This allows customization for the individual device. The
range for the capture timeout is 15
to 255 seconds.
The
errors
parameter is the number of consecutive errors required before the application
will remove the printer from service. The "off" option will disable the auto remove printer
function. The range of
errors
is 1 to 10.
8.11 V
ERIFY
C
ONFIGURED
O
PTIONS
–
VERIFY
|
VFY
Syntax: verify | vfy
The
verify (vfy)
command is only visible when the application is logged in. The command
is used to display the configured options.
8.12 R
ESTORING THE
P
RINTER
C
ONNECTION
–
RS
|
RESTORE
Syntax: rs | restore prt
The
rs prt
command is only visible when the application is logged in. It puts the printer
connection "in service". The printer connection must be "in service" before a connection to
a RFC1179 printer will be attempted.
8.13 R
EMOVING THE
P
RINTER
C
ONNECTION
–
RM
|
REMOVE
Syntax: rm | remove prt
The
rm prt
command is only visible when the application is logged in. It takes the printer
connection "out of service". Any existing connections will be taken down and no new
connections will be established even if there is data to print.
8.14 D
ISPLAYING
C
URRENT
C
ONNECTIONS
–
DC
|
DCONN
Syntax: dc | dconn