background image

 

11

No 

SDI Input 

YUV Output 

DIP Switch Setup (D6 reserved) 

57 

1080/59.94i 
16:9 

480i 
16:9 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON ON OFF 

58 

1080/59.94i 
16:9 

480 
4:3 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON OFF 

OFF 

59 

1080/59.94i 
16:9 

576i 
16:9 

D1 D2 D3 D4 D5 
ON ON OFF 

ON OFF 

60 

1080/59.94i 
16:9 

576i 
4:3 

D1 D2 D3 D4 D5 
ON ON OFF 

OFF 

OFF 

No 

SDI Input 

CVBS Output 

DIP Switch Setup (D6 reserved) 

61 

1080/59.94i 
16:9 

480i 
16:9 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON ON ON 

62 

1080/59.94i 
16:9 

480 
4:3 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON OFF 

ON 

63 

1080/59.94i 
16:9 

576i 
16:9 

D1 D2 D3 D4 D5 
ON ON OFF 

ON ON 

64 

1080/59.94i 
16:9 

576i 
4:3 

D1 D2 D3 D4 D5 
ON ON OFF 

OFF 

ON 

No 

SDI Input 

YUV Output 

DIP Switch Setup (D6 reserved) 

65 

1080/50i 
16:9 

480i 
16:9 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON ON OFF 

66 

1080/50i 
16:9 

480 
4:3 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON OFF 

OFF 

67 

1080/50i 
16:9 

576i 
16:9 

D1 D2 D3 D4 D5 
ON ON OFF 

ON OFF 

68 

1080/50i 
16:9 

576i 
4:3 

D1 D2 D3 D4 D5 
ON ON OFF 

OFF 

OFF 

No 

SDI Input 

CVBS Output 

DIP Switch Setup (D6 reserved) 

69 

1080/50i 
16:9 

480i 
16:9 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON ON ON 

70 

1080/50i 
16:9 

480 
4:3 , 0 IRE 

D1 D2 D3 D4 D5 
ON OFF 

ON OFF 

ON 

71 

1080/50i 
16:9 

576i 
16:9 

D1 D2 D3 D4 D5 
ON ON OFF 

ON ON 

72 

1080/50i 
16:9 

576i 
4:3 

D1 D2 D3 D4 D5 
ON ON OFF 

OFF 

ON 

 
 
 

No 

SDI Input 

YUV Output 

DIP Switch Setup (D6 reserved) 

Summary of Contents for DAC-50

Page 1: ...HD SD SDI to Component YUV Converter DAC 50 Quick Start Guide www datavideo tek com...

Page 2: ...1 Table of Contents Warnings and Precautions 2 What s in the box 4 Introduction 4 Features 4 Functions 5 DIP Switch Function 7 Specification 16 Service Support 17...

Page 3: ...t on a bed sofa rug or similar surface as the ventilation openings on the bottom of the cabinet will be blocked This unit should never be placed near or over a heat register or radiator This unit shou...

Page 4: ...r warranty Refer all service issues to qualified service personnel 13 Unplug this product from the wall outlet and refer to qualified service personnel under the following conditions a When the power...

Page 5: ...esolution by slide switch Features 6 Mode Resolutions DC 12V input HD SD SDI Video Input BNC x1 Video Output HD SD YUV component x1 HD SD SDI Input Resolutions 720x480 Interlace 720x576 Interlace 1280...

Page 6: ...DI Input 4 2 2 SDI Video data supports SMPTE 292M standard at 1 5G Mbps SDI transfers professional level video signals and it s can connect to long distance transmission systems DIP Switch Use slide s...

Page 7: ...he supplied 12V 1 5A PSU to this socket The connection can be secured by screwing the outer fastening ring of the DC In plug to the socket Power Switch Switches the power On Off HD SD YUV HD SD YUV co...

Page 8: ...OFF OFF 3 480i 4 3 720 50p 16 9 D1 D2 D3 D4 D5 OFF ON OFF ON OFF 4 480i 4 3 720 50p 4 3 D1 D2 D3 D4 D5 OFF ON OFF OFF OFF 5 480i 4 3 1080 59 94i 16 9 D1 D2 D3 D4 D5 OFF OFF ON ON OFF 6 480i 4 3 1080...

Page 9: ...D3 D4 D5 OFF OFF ON ON OFF 18 720 59 94p 16 9 1080 59 94i 4 3 D1 D2 D3 D4 D5 OFF OFF ON OFF OFF 19 720 59 94p 16 9 1080 50i 16 9 D1 D2 D3 D4 D5 OFF ON ON ON OFF 20 720 59 94p 16 9 1080 50i 4 3 D1 D2...

Page 10: ...F ON 31 720 59 94p 16 9 576i 16 9 D1 D2 D3 D4 D5 ON ON OFF ON ON 32 720 59 94p 16 9 576i 4 3 D1 D2 D3 D4 D5 ON ON OFF OFF ON No SDI Input YUV Output DIP Switch Setup D6 reserved 33 720 50p 16 9 480i 1...

Page 11: ...No SDI Input CVBS Output DIP Switch Setup D6 reserved 47 720 50p 16 9 480i 16 9 7 5 IRE D1 D2 D3 D4 D5 ON OFF OFF ON ON 48 720 50p 16 9 480 4 3 7 5 IRE D1 D2 D3 D4 D5 ON OFF OFF OFF ON No SDI Input Y...

Page 12: ...D3 D4 D5 ON ON OFF ON ON 64 1080 59 94i 16 9 576i 4 3 D1 D2 D3 D4 D5 ON ON OFF OFF ON No SDI Input YUV Output DIP Switch Setup D6 reserved 65 1080 50i 16 9 480i 16 9 0 IRE D1 D2 D3 D4 D5 ON OFF ON ON...

Page 13: ...76 1080 59 94i 16 9 480 4 3 5 IRE D1 D2 D3 D4 D5 ON OFF OFF OFF ON No SDI Input YUV Output DIP Switch Setup D6 reserved 77 1080 50i 16 9 480i 16 9 7 5 IRE D1 D2 D3 D4 D5 ON OFF OFF ON OFF 78 1080 50i...

Page 14: ...4 D5 ON ON OFF ON ON 88 480i 16 9 576i 4 3 D1 D2 D3 D4 D5 ON ON OFF OFF ON No SDI Input YUV Output DIP Switch Setup D6 reserved 89 576i 4 3 480i 16 9 0 IRE D1 D2 D3 D4 D5 ON OFF ON ON OFF 90 576i 16 9...

Page 15: ...0 4 3 7 5 IRE D1 D2 D3 D4 D5 ON OFF OFF OFF ON No SDI Input YUV Output DIP Switch Setup D6 reserved 101 576i 4 3 480i 16 9 7 5 IRE D1 D2 D3 D4 D5 ON OFF OFF ON OFF 102 576i 16 9 480 4 3 7 5 IRE D1 D2...

Page 16: ...D1 D2 D3 D4 D5 OFF OFF OFF OFF OFF 110 720 50p 16 9 720 50p 4 3 D1 D2 D3 D4 D5 OFF ON OFF OFF OFF 111 1080 59 94i 16 9 1080 59 94i 4 3 D1 D2 D3 D4 D5 OFF OFF ON OFF OFF 112 1080 59 94i 16 9 1080 50i...

Page 17: ...ors 75Ohms HD YUV signal Bandwidth 30MHz 3dB S N Ratio 60 dB Multiburst 1dB at 30Mhz SD YUV signal Non Linearity 1 S N Ratio 60 dB Multiburst 1 dB Y 5MHz PbPr 2 5MHz Operating Temperature 0 C to 40 C...

Page 18: ...e BV Tel 31 30 261 96 56 Fax 31 30 261 96 57 E Mail service datavideo nl Datavideo UK Limited Tel 44 1457 851 000 Fax 44 1457 850 964 E Mail sales datavideo co uk Datavideo Technologies Co Ltd Tel 886...

Reviews: