65
System Diagram
Check the Current Firmware Version
1. Please use two fingers to slide up on the KMU-300 touch screen display to show KMU-
300’s OSD
Menu.
2. Please tap “FW>FW Version” and then you can see several firmware version numbers including
MB, DB, KB, FPGA and Panel.
Firmware Update
For the way to update the KMU-300 firmware, please refer to the descriptions below.
Updating the firmware by combining a USB Flash Drive and KMU-
300’s OSD Menu
At first, please confirm that the latest firmware file is downloaded from Datavideo
official website’s product page.
Please unzip the downloaded firmware and then please save the six firmware files
including DBSPCSC.bin
、
KMU300MB.bin
、
KMU300CF.bin
、
KMU300DB.bin
、
KMU300KB.bin and KMU300PL.bin into the root directory of your USB flash drive.
Please turn on the power of the KMU-300 and then please insert your USB Flash Drive
into the F/W UPGRADE interface which is located on the rear panel of the KMU-300.
Please slide up by two fingers on KMU-
300’ touch panel display to show the OSD menu
.
Pl
ease tap “FW>FW Update>Update”, and then the firmware update will be started
automatically.