7.9. Rounding displayed value
(07. menu item)
Function
In some case it can be useful to round the displayed value.
E.g. the measured physical quantity is noisy.
In this menu item you can select a rounding value.
Sequence of operation
1. Enter the menu by typing a supervisor code.
The way the code should be type is described in Chapter
7.1. Typing the code in.
You see on the display:
.
2. Keep stepping by pressing the
▲
button as long as you
see this menu item:
(
Rou
nding).
3. Enter the menu item by pressing the
ENTER
button.
4. You see this
. on the display. The text is blinking
indicating that it can be modify.
5. Pressing the
▲
button you can select from the following
options:
•
= no rounding [Factory default]
•
= rounding to 2
•
= rounding to 5
•
= rounding to 10
•
= rounding to 20
•
= rounding to 50
•
= rounding to 100
Exit from menu item
1. After finishing the settings, press the
MENU
button to exit
from the given menu item, and you see:
.
(2. If you want to change the settings you have done just
now, or if you just want to check what you have typed in, go
on with the operation from point 3. of the
Sequence of
operations
.)
(3. If you don’t want to exit the menu (you want to do further
settings), then you may select the desired menu items by
pressing the
▲
button.)
Exit from menu
Press the
MENU
button. First the mnemonic
(
Save
),
then the mnemonic
(
Exit
) are shown on the display.
With this the storing of the settings is completed. The
instrument has exited the menu and goes on with the
measurement.
Summary of Contents for DT1400 RL2 IA
Page 1: ...DT1400 xx xx Limit switch Operating Instructions ...
Page 68: ...DT1400 xx xx 68 20170920 V0 10 2 Application example Analog output option ...
Page 69: ...DT1400 xx xx 20170920 V0 69 RL4 option ...
Page 70: ...DT1400 xx xx 70 20170920 V0 TS option ...
Page 71: ...DT1400 xx xx 20170920 V0 71 ...
Page 72: ......