DT1400 xx xx
46
20170920-V0
Limit output hold mode
In case of basic operating mode the limit output is switching
on or switching off when the conditions are exist. In limit
output hold mode the output is kept in switched state and
only by pressing
ENTER
button can be reset (limit signaling
acknowledge).
Sequence of operations
31. Keep stepping by pressing the
▲
button as long as you
see this sub-menu item:
(
L
imit
1
Hol
d).
32. Enter by pressing the
ENTER
button.
33. By pressing
▲
button you can switch on or off the hold
mode:
•
: (
Off
= switched off). The limit output is working
according the display value and the limit value setting
(factory default).
•
: (
Hold
). The limit output is switching on according
the display value and the limit value setting, but it switching
only off by pressing
ENTER
button (limit signaling
acknowledge).
Exit from the menu item
1. After finishing the settings, press the
MENU
button to exit
from the menu item, and you see this:
. Press the
MENU
button to exit from the menu item, and you see this:
.
(2. If you want to change the setting you have done just
now, or if you just want to check what you have typed in, go
on with the operation from point 3 of the
Sequence of
operations.
)
(3. When you don’t want to exit menu because you are
going to do other settings in other menu items press
▲
button to step to the following menu item.
Exit from the menu
Press the
MENU
button. First the mnemonic
(
Save
),
then the mnemonic
(
Exit
) are shown on the display.
With this the storing of the settings is completed. The
instrument has exited the menu and goes on with the
measurement.
Summary of Contents for DT1400 RL2 IA
Page 1: ...DT1400 xx xx Limit switch Operating Instructions ...
Page 68: ...DT1400 xx xx 68 20170920 V0 10 2 Application example Analog output option ...
Page 69: ...DT1400 xx xx 20170920 V0 69 RL4 option ...
Page 70: ...DT1400 xx xx 70 20170920 V0 TS option ...
Page 71: ...DT1400 xx xx 20170920 V0 71 ...
Page 72: ......