background image

Datecs    

                                                                                                                            USERS MANUAL 

                                                                                                                                                                   21.06.2011 

 

14 

MODE R - REGISTERING 

 

1. In order to access the R mode, from the ‘OFF’ state press key 1. 
 
2.  On  the  left  upper  display  corner  the  letter  'R'  appears  and  the 
operator is invited to enter his password.  
Enter the numeric password sequence and press TOTAL

FJALEKAL--------

R

 

 
 

FUNCTION OF THE KEYS IN 'REGISTERING' MODE 

 

Choosing the item:

  

 

DP1

 ÷ 

DP4

  to access respectively PLU 1 ÷ PLU 4; 

DP1 

÷

,

  

DP4

 to access respectively PLU 5 ÷ PLU 8; 

 
The key pressing causes accumulation into the customer bill and also into the quantity and turnover registers for 
the department chosen. The value entered before choosing the department is considered as a price. If the price is 
not entered, the programmed price is used. 
Note: It is not allowed a sale with a zero  price. This will cause alarm signal to be produced and error message to 
be shown on the display. 

PLU   

 
Specifies, that the previously entered number is a PLU-code of an item. Causes an accumulation of the selected 
PLU into the customer's bill. When the PLU-code is entered, the decimal point is ignored and the value entered is 
assumed as integer one.  
Note: If the price programmed is zero or the name is not programmed (or any of the item parameters is not 
allowable) -  the operation will be refused. 

PRC 

 
Specifies that the previously entered value is a price: 
The decimal point position on the display is checked. This key is used for entering a free price for department or 
item. First, the price value is entered, than <PRC> is pressed. Than the item desired should be specified. 

BAR 

 
Select an item by its barcode 
By pressing the key BAR after entering a number, on the display appears 'BARKODE’, and makes the sale with 
the item which has such barcode

 

 

 
Change language 

 
Entering a quantity 
1. Specifies, that the value entered is a quantity. The decimal point position on the display is checked.  
2. When the ECR works with a scale, the pressing of that key without prior entered value will cause the quantity 
from the scale to be received. 

VD 

 
Void functions  
1.  With  this  key  immediately  after  an  item  is  accumulated  a  VOID  (cancellation)  of  that  sale  is  performed.  The 
consecutively pressing of that key will cause consecutively cancellation of all sales in the receipt. 
2. In order to cancel a sale which is not the last made(deep void), in an open receipt the following keys should be 
consecutively pressed:  
 

 <

and <VD>, than the sale parameters should be entered again. This operation can not be performed, 

if the sale parameters are not the same as in the sale to be cancelled. 
Note: The operator should enter the same parameters as they are printed in the receipt on the row which he want 
to cancel. If there are surcharges/discharges made over the item, they will be cancelled together with the sale 
cancellation. 
3.

 

Execution of a storno-operation: 

             <

and <VD>        -   the text "KORREKTIM" appears on display, 

             <VD> (second time) -   the text "KTHIM I ARTIKUJ." appears on display, 
than the sale parameters should be entered again. 
   The storno-operaion will be executed if the turnover of the corresponding tax group does not become negative; 
the text printed on the receipt is "

 KTHIM I ARTIKUJVE".

 

Summary of Contents for dp-55d kosovo

Page 1: ...Datecs USERS MANUAL 21 06 2011 1 ELECTRONIC CASH REGISTER DP 55D Kosovo...

Page 2: ...eration for their correct usage and maintenance DP 55D are cash registers with possibilities which conform to the customer service requirements and financial accounting in shops supermarkets pharmacie...

Page 3: ...re exit b ECR which serves one stand Types of payment 1 Cash cheque credit card coupon 2 Cash with alternative currency USD ECR operation modes REG Registration Programming Report Test Z Report with c...

Page 4: ......

Page 5: ...d which able both to the customer and to the operator to see the information displayed SWITCHING THE ECR ON OFF The ECR comes complete with mains adapter The adapter is intended to operate with 220VAC...

Page 6: ...ettings 5 S Service mode available If the service jumper is activated 6 GPRS Configuration GPRS available If the service jumper is activated 7 FM Read FM available If the service jumper is activated 8...

Page 7: ...number business registration number the Identification number of the tax obligated person and VAT rates 3 Fiscalization to ECR FUNCTION OF THE KEYS IN PROGRAMMING MODE The programming of parameters is...

Page 8: ...L must be pressed If the operator omit to press the TOTAL key the last made modifications will be lost When editing a symbol field the symbols are chosen by consecutively pressing a key and if the key...

Page 9: ...guage Up to 22 characters Default For row 1 20 PLU 1 PLU 20 For row 21 5000 filled with spaces 3 Price Up to 8 digits Default 0 00 5 Inventory group 0 9 Default For row 1 8 1 8 For row 9 5000 9 Note I...

Page 10: ...s key in order to move on the field 13 the item s name in albanian language 5 Press key STL in order to move in editing mode 6 Enter the name of the item BUKA as the follows B 8 8 U 2 2 K 5 5 A 8 7 Ac...

Page 11: ...eipts in REG mode 0 1 2 0 Disabled permitted sales from the keyboard of ECR there isn t communication with PC there isn t mode fiscal printer 1 Enabled programming between the receipts in REG mode per...

Page 12: ...xt in english During fiscalization the texts are recorded in the fiscal memory After fiscalization they can be changed only if the service jumper is activated Up to 20 changes per fiscal memory are po...

Page 13: ...x obligated person 15 symbols Default 0 Note If the default value of the identification numbers of the tax obligated person is not changed this will not permit the setting of the fiscal memory into us...

Page 14: ...entered than PRC is pressed Than the item desired should be specified BAR Select an item by its barcode By pressing the key BAR after entering a number on the display appears BARKODE and makes the sa...

Page 15: ...y PY2 is pressed A dialog screen appears 3 KUPON 4 USD 2 QEK Press the appropriate numeric key to choose the payment desired When the choice is made if possible a payment is performed A mixed payment...

Page 16: ...ntered and after the is used it will cause the prior entered value to be adds to the subtotal Discount by value The using of this sequence will cause the prior entered value to be subtracted from the...

Page 17: ...item of the range is determined with entering the row number from table 1 and presiing the or key Using the keys and you can move forward and backward over the table 1 rows Pressing the key TOTAL sta...

Page 18: ...d the registers involved are cleared automatically When the field 7 of table 2 is set to 1 the turnovers and quantities of the items are also cleared STL Reporting and clearing the operators debts On...

Page 19: ...mber Detailed Month Report 3 STL VD X MMYY Detailed report for period determined by date to date that is submitted at GPRS terminal 1 STL X DDMMYY DDMMYY BAR Month report that is submitted at GPRS ter...

Page 20: ...field 9 For programming and reporting is used the application Ecr Tool or its analog OFF LINE ERROR CODES AND MESSAGES Error codes Error code Description Solution ERROR 01 Printing device failure ERRO...