Control

 

 

WallUnits

 

 
The  audio  source  for  a  zone  can  be  selected  by 
pressing  ‘channel  +’  or  ‘channel  -‘.  The  number  of 
sources  and  sequence  depends  on  the  matrix 
configuration. By pressing the ‘c’ and ‘channel -
‘ simultaneously, the local audio input will be selected.  
 
 
 
 
 

 
Adjusting  the  volume  for  a  zone  is  done  by  pressing 
‘volume  +’  or  volume  -‘.  By  holding  the  button,  volume 
can be increased or decreased. Pressing both + and – 
buttons at the same time will mute the zone. Paging to 
the zone is always available.  
 
 
 
 
 

 

  When  room  combining  is  active  slave  zones  are  not  able  to  select  the  audio 

source. Setting the source is only available for the master zone. Slave  zones do 
have the possibility to adjust volume. 

  On  the  MAX8.8D  en  MAX8.16D  RDS  or  meta  data  can  bes  end  to  the  wallunit 

displays. 

 

Local audio input

 

 
Using  the  local  audio  input  MRA1  or  MRA2  an  external 
audio  source  like  an  MP3  player,  microphone,  laptop  or 
mixing  desk  can  be  added  to  the  system.  The  MRA1  is 
equipped with a balanced audio input on XLR. This way a 
microphone  can  easily  be  connected.  For  connecting  a 
CD player or other RCA sources a conversion cable must 
be connected. 
 
Using  the  Mic/Line  switch  the  input  sensitivity  can  be 
adjusted.  Set  is  to  line  when  line  level  signal  is  present. 
The MRA2 is equipped with both balanced XLR and RCA line level inputs. Each input 
can be independently adjusted making a small mix between line and microphone on 
the same input. 
The Clip/Ovl LED will blink on overloading the input signal.

 

 

!

 

 

MRC 

MRA

 

Summary of Contents for Musicall MAX8.16

Page 1: ...MAX 8 8 MAX8 8D MAX8 16 MAX8 16D MusiCall User manual ...

Page 2: ...UK MusiCall user manual Notes ...

Page 3: ... may only be connected to a legally approved earthened mains power supply 11 The power cable or power cord must be positioned such that it cannot be walked on in normal use and objects which might damage the cable or cord cannot be placed on it or against it Special attention must be paid to the point at which the cable is attached to the equipment and where the cable is connected to the power sup...

Page 4: ...ith a quadruple DAB FM and WEB tuner Model with 8 stereo mono zones 3 stereo 6 mono RCA inputs and optional 8 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local audio input Configuration and control possible using the internal webserver Musicall MAX8 8D The MAX8 16 is the standard central matrix Model with 8 stereo 16mono zones 8 stereo 16 mono RCA inputs and o...

Page 5: ...nput Three inputs can be used to activate room combining One input can be used to activate the priority audio input The last input can be used to connect an external system mute for fire alert and evacuation purposes The telephone audio input can be configured to auto answer or audio detect Logic IO Using the logic IO paging can be remotely activated The logic output scan be configured to external...

Page 6: ... The MAX matrices offer full control over IP using the internal webserver Users can access the individual zone page or global control all zones The interface allows audio source selection volume control and EQ settings Zones can be locked for webcontrol using a simple four digit code The internal webpage can be accessed using http musicall or by entering the IP address of your matrix into the webb...

Page 7: ...one Slave zones do have the possibility to adjust volume On the MAX8 8D en MAX8 16D RDS or meta data can bes end to the wallunit displays Local audio input Using the local audio input MRA1 or MRA2 an external audio source like an MP3 player microphone laptop or mixing desk can be added to the system The MRA1 is equipped with a balanced audio input on XLR This way a microphone can easily be connect...

Page 8: ...e Groups 1 8 or 1 16 can only be changed using the configuration pages By default these groups are set to zone 1 16 Entering the programming menu Press the P key to enter the programming menu The programming screen will appear By default the programming menu will start in group A Select the group that needs to be changed In programming mode the buttons 1 16 indicate all zones The green LED s indic...

Page 9: ...s Booting During the First 15 seconds after booting the boot screen logo will appear During this time all available information about the matrix setups radio stations and web streams is loaded DAB FM tuner Monitoring the tuner is made possible within the Tuner tab The desired tuner can be selected Switching between DAB and FM is only made possible within the configuration pages and can not be chan...

Page 10: ...ious Select previous preset Stop Stop playout Play Start playout Next Select next preset MAX Matrix Within the MAX tab all available audio sources within the MAX Matrix can be monitored Using the monitor functionality all sources can easily be adjusted during installation or trouble shooting purposes During monitoring the MAX sources the audio outputs 8A zone 8 and 8B zone 16 are not available Con...

Page 11: ...tput volume adjustment 0 50 dB steps of 0 5 dB then mute 75 dB THD N 0 08 CCIR RMS 0dBu FREQUENCY RESPONCE Input to output 25 Hz 25 kHz 1 dB WALLUNIT CONNECTION Output voltage 24V Maximum output current 110mA automatic fuse CONSOLE CONNECTORS Output voltage 24V Maximum output current 500mA automatic fuse COMMUNICATION Baudrate RS232 14kbps USB USB2 Ethernet 10 100MBit auto select GENERAL Mains sup...

Page 12: ...bout the Musicall system parts and other products you can contact your local dealer or Dateq Audio Technologies B V De Paal 37 Telephone 0031 36 54 72 222 1351 JG Almere Fax 0031 36 53 17 776 The Netherlands E mail info musicall nl Internet www musicall nl ...

Reviews: