Consoles

 

 

Paging zones 

Each button contains a zone or number off 
zones  that  can  be  changed  using  the 
configuration  website.  On  addressing  a 
zone,  the  LED  turns  red.  At  this  point  the 
‘chime’  is  heard.  On  the  LED  turning 
green,  a  voice  call  can  be  made.  On 
releasing the zone button the zone returns 
in the state it was before paging started.  
 
 
 

  In  case  room  combining  is  active  and  a  slave  zone  is  addressed  but  not  the 

master zone paging will not be active in that specific slave zone. 

  In case room combining is active and a master zone is addressed all slave zones 

will be addressed too. 

  Paging to a zone will always be active even when a zone is set to silence. 

  Paging will not be active when a system mute by fire alert or evacuation is active. 

 

Adjusting configuration

 

Using the console group paging can be set and adjusted. Programming through the 
paging console only groups A, B, C and D are available. Groups 1…8 or 1…16 can 
only  be  changed  using  the  configuration  pages.  By  default  these  groups  are  set  to 
zone 1…16. 
 

Entering the programming menu.

 

Press the ‘P’ key to enter the programming menu. 
The programming screen will appear. By default the programming menu will start in 
group ‘A’. Select the group that needs to be changed. 
 
In programming mode the buttons 1…16 indicate all zones. The green LED’s indicate 
the  active  zones  in  the  selected  group.  Zones  can  be  added  by  pressing  the  zone 
buttons 1…16. In case a zone is selected stereo both zone outputs are automatically 
selected when adding the zone. Selected zones and groups are automatically saved 
into the matrix configuration. 
 
Existing paging groups can later on easily be changed by pressing one of the group 
buttons.  All  zones  within  the  selected  Group  will  light  up  green.  By  pressing  the 
buttons 1…16 zones can be added or removed. 
 

  A zone can be selected to one or more groups. 

  Paging groups are automatically stored. 

  Groups 1…16 can only be changed using the internal configuration webpage. 

  Paging to the master of room combined zones are active in slave zones too. 

 
 
 
 
 
 
 
 
 
 

!

 

!

 

Summary of Contents for Musicall MAX8.16

Page 1: ...MAX 8 8 MAX8 8D MAX8 16 MAX8 16D MusiCall User manual ...

Page 2: ...UK MusiCall user manual Notes ...

Page 3: ... may only be connected to a legally approved earthened mains power supply 11 The power cable or power cord must be positioned such that it cannot be walked on in normal use and objects which might damage the cable or cord cannot be placed on it or against it Special attention must be paid to the point at which the cable is attached to the equipment and where the cable is connected to the power sup...

Page 4: ...ith a quadruple DAB FM and WEB tuner Model with 8 stereo mono zones 3 stereo 6 mono RCA inputs and optional 8 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local audio input Configuration and control possible using the internal webserver Musicall MAX8 8D The MAX8 16 is the standard central matrix Model with 8 stereo 16mono zones 8 stereo 16 mono RCA inputs and o...

Page 5: ...nput Three inputs can be used to activate room combining One input can be used to activate the priority audio input The last input can be used to connect an external system mute for fire alert and evacuation purposes The telephone audio input can be configured to auto answer or audio detect Logic IO Using the logic IO paging can be remotely activated The logic output scan be configured to external...

Page 6: ... The MAX matrices offer full control over IP using the internal webserver Users can access the individual zone page or global control all zones The interface allows audio source selection volume control and EQ settings Zones can be locked for webcontrol using a simple four digit code The internal webpage can be accessed using http musicall or by entering the IP address of your matrix into the webb...

Page 7: ...one Slave zones do have the possibility to adjust volume On the MAX8 8D en MAX8 16D RDS or meta data can bes end to the wallunit displays Local audio input Using the local audio input MRA1 or MRA2 an external audio source like an MP3 player microphone laptop or mixing desk can be added to the system The MRA1 is equipped with a balanced audio input on XLR This way a microphone can easily be connect...

Page 8: ...e Groups 1 8 or 1 16 can only be changed using the configuration pages By default these groups are set to zone 1 16 Entering the programming menu Press the P key to enter the programming menu The programming screen will appear By default the programming menu will start in group A Select the group that needs to be changed In programming mode the buttons 1 16 indicate all zones The green LED s indic...

Page 9: ...s Booting During the First 15 seconds after booting the boot screen logo will appear During this time all available information about the matrix setups radio stations and web streams is loaded DAB FM tuner Monitoring the tuner is made possible within the Tuner tab The desired tuner can be selected Switching between DAB and FM is only made possible within the configuration pages and can not be chan...

Page 10: ...ious Select previous preset Stop Stop playout Play Start playout Next Select next preset MAX Matrix Within the MAX tab all available audio sources within the MAX Matrix can be monitored Using the monitor functionality all sources can easily be adjusted during installation or trouble shooting purposes During monitoring the MAX sources the audio outputs 8A zone 8 and 8B zone 16 are not available Con...

Page 11: ...tput volume adjustment 0 50 dB steps of 0 5 dB then mute 75 dB THD N 0 08 CCIR RMS 0dBu FREQUENCY RESPONCE Input to output 25 Hz 25 kHz 1 dB WALLUNIT CONNECTION Output voltage 24V Maximum output current 110mA automatic fuse CONSOLE CONNECTORS Output voltage 24V Maximum output current 500mA automatic fuse COMMUNICATION Baudrate RS232 14kbps USB USB2 Ethernet 10 100MBit auto select GENERAL Mains sup...