DAB+ / FM QUAD Tuner

 

 
The MAX8.8D and MAX8.16D are equipped with a quadruple DAB+/FM and a single 
web stream tuner. Using the touch screen 
display control is made possible. Adding to 
the  tuner  functionality  monitoring  all 
sources  though  the  headphone  is  made 
possible  and  vital  information  about  the 
system can be reviewed.  
 
 
 
 
 

Antenna 

For  use  of  the  four  tuners  the  system  has  to  be  connected  to  a  CAI 
(Central Antenna Installation) or external outdoor antenna. For the use of 
DAB+ an external antenna is necessary when a CAI installation does not 
provide DAB+. When using the Web stream encoder the matrix needs to 
be connected to a local area network with internet access. 
 

 
Booting 

During the First 15 seconds after booting the boot screen logo will 
appear. During this time all available information about the matrix, 
setups, radio stations and web streams is loaded. 
 
 

DAB+/FM tuner 

Monitoring  the  tuner  is  made  possible  within  the 
Tuner  tab.  The  desired  tuner  can  be  selected. 
Switching  between  DAB+  and  FM  is  only  made 
possible  within  the  configuration  pages  and  can  
not be changed using the front panel display. 
  
Adjusting  the  tuners  frequency  or  preset  will  affect 
the zones that have selected the tuner as source.  
 

Control 

Using the front panel display all available stations and presets can be monitored.  
 

 

 

Seek down 

 

The tuner will select the last in list radio station 

 

 

Previous 

 

The tuner will select the previous preset 

 

 

Next 

 

The tuner will select the next preset 

 

 

Seek up 

 

The tuner will select the next radio station 

 

 

 

 

Signal 

 

Signal strength for the selected tuner 

 

!

 

Summary of Contents for Musicall MAX8.16

Page 1: ...MAX 8 8 MAX8 8D MAX8 16 MAX8 16D MusiCall User manual ...

Page 2: ...UK MusiCall user manual Notes ...

Page 3: ... may only be connected to a legally approved earthened mains power supply 11 The power cable or power cord must be positioned such that it cannot be walked on in normal use and objects which might damage the cable or cord cannot be placed on it or against it Special attention must be paid to the point at which the cable is attached to the equipment and where the cable is connected to the power sup...

Page 4: ...ith a quadruple DAB FM and WEB tuner Model with 8 stereo mono zones 3 stereo 6 mono RCA inputs and optional 8 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local audio input Configuration and control possible using the internal webserver Musicall MAX8 8D The MAX8 16 is the standard central matrix Model with 8 stereo 16mono zones 8 stereo 16 mono RCA inputs and o...

Page 5: ...nput Three inputs can be used to activate room combining One input can be used to activate the priority audio input The last input can be used to connect an external system mute for fire alert and evacuation purposes The telephone audio input can be configured to auto answer or audio detect Logic IO Using the logic IO paging can be remotely activated The logic output scan be configured to external...

Page 6: ... The MAX matrices offer full control over IP using the internal webserver Users can access the individual zone page or global control all zones The interface allows audio source selection volume control and EQ settings Zones can be locked for webcontrol using a simple four digit code The internal webpage can be accessed using http musicall or by entering the IP address of your matrix into the webb...

Page 7: ...one Slave zones do have the possibility to adjust volume On the MAX8 8D en MAX8 16D RDS or meta data can bes end to the wallunit displays Local audio input Using the local audio input MRA1 or MRA2 an external audio source like an MP3 player microphone laptop or mixing desk can be added to the system The MRA1 is equipped with a balanced audio input on XLR This way a microphone can easily be connect...

Page 8: ...e Groups 1 8 or 1 16 can only be changed using the configuration pages By default these groups are set to zone 1 16 Entering the programming menu Press the P key to enter the programming menu The programming screen will appear By default the programming menu will start in group A Select the group that needs to be changed In programming mode the buttons 1 16 indicate all zones The green LED s indic...

Page 9: ...s Booting During the First 15 seconds after booting the boot screen logo will appear During this time all available information about the matrix setups radio stations and web streams is loaded DAB FM tuner Monitoring the tuner is made possible within the Tuner tab The desired tuner can be selected Switching between DAB and FM is only made possible within the configuration pages and can not be chan...

Page 10: ...ious Select previous preset Stop Stop playout Play Start playout Next Select next preset MAX Matrix Within the MAX tab all available audio sources within the MAX Matrix can be monitored Using the monitor functionality all sources can easily be adjusted during installation or trouble shooting purposes During monitoring the MAX sources the audio outputs 8A zone 8 and 8B zone 16 are not available Con...

Page 11: ...tput volume adjustment 0 50 dB steps of 0 5 dB then mute 75 dB THD N 0 08 CCIR RMS 0dBu FREQUENCY RESPONCE Input to output 25 Hz 25 kHz 1 dB WALLUNIT CONNECTION Output voltage 24V Maximum output current 110mA automatic fuse CONSOLE CONNECTORS Output voltage 24V Maximum output current 500mA automatic fuse COMMUNICATION Baudrate RS232 14kbps USB USB2 Ethernet 10 100MBit auto select GENERAL Mains sup...