background image

UK

DATEQ SPL-D3 Manual

Technical specifications

11

Technical specifications

Inputs

Mic (Measurement microphone)

XLR-3 female. Use only the original DCM-5 

       

microphone.

Common

Audio

Frequency response 30Hz...16kHz @ -1,5dB
Signal/ noise ratio

>90dB

Memory

4GB SDHC
365 days * sound pressure information (resolution 1 minute)

External memory

Up to 32Gb FAT32 USB drive
30 days * sound pressure information (resolution 1 minute) export in .CSV format.

Norm

EU:

Measurement chain designed to comply according specifications 

IEC-61672-1 class 2

France: Measurement chain designed to comply according specifications 

NFS 31-122-1-2017 and decrét 2017-1244

BE:

Measurement chain designed to comply according specifications

VLAREM-II Cat.1, Cat.2 and Cat.3

DE:

Measurement chain designed to comply according specifications

DIN-61672, DIN-60651 and DIN15905-5

Power supply 

Supply voltage

24 volt

Power usage (max) 24 Watt
Power usage (normal operation)

12 Watt

Dimensions and weight

Front 282mm x 192mm
Depth 55mm
Weight

2.8kg

*

Sound level data and event logging are stored for maximal 365 days or less when memory is full. The memory system will delete and override oldest data first. 

SPL-D3_200101_V1.0EN

Summary of Contents for SPL-D3

Page 1: ...SPL D3_200101_V1 0EN SPL D3 Multi Color Display Sound level logger Manual ...

Page 2: ...it s designed functionalities it is considered to be used and installed solely by professional and certified installers and is not intended for consumer usage or resale Consumer use is not supported by the manufacturer SPL D3_200101_V1 0EN ...

Page 3: ... The equipment may only be connected to a legally approved earthed mains power supply 11 The power cable or power cord must be positioned such that it cannot be walked on in normal use and objects that might damage the cable or cord cannot be placed on it or against it Special attention must be paid to the point at which the cable is attached to the equipment and where the cable is connected to th...

Page 4: ... Technical specifications 13 Inputs 13 Common 13 Introduction configuration 19 Installation 20 Configuration 20 Configuration license 21 Unlocking the limiter 21 Live 22 Display configuration 23 Microphone 24 Illumination 24 Time slots 24 Circuit breaker 24 Calibration 25 System 25 History 26 Product support 29 ...

Page 5: ... SPL D3 a windows computer with USB support is required The SPL D3 uses a measurement microphone to determine the actual sound level When measurement shows the sound levels are about to exceed the display will change from green to orange and red when levels are actually exceeded The special calender functions allow for different sound levels during the day and year With the special SRL 1 circuit b...

Page 6: ...ns Microphone input XLR 3 pin female Pin Function Description 1 Ground Audio ground 2 Audio Supply and audio 3 Audio Supply and audio Table 1 microphone connections USB port USB B female Pin Function Description 1 VCC Supply 2 Data Data 3 Data Data 4 GND Ground Table 2 USB connections Network port RJ45 female Pin Function Description 1 TX D Data 2 TX D Data 3 RX D Data 4 Not in use 5 Not in use 6 ...

Page 7: ...thened with standard microphone cable Pay attention to the polarity of the wiring If the microphone is wrongly connected it won t work The limiter will give an error message and the volume will be extremely reduced The microphone should be installed so that it hears both sound from the speakers as well as the sound from the crowd in the room The microphone can be placed closer to the speakers when...

Page 8: ...iter 4 Displays 2 and 3 Shows the actual measured dB value in green orange or red Both displays can be selected with an independent value filter 5 Leq min Shows the used time frame for Leq In this example 10 minutes for display 2 and 60 minutes for display 3 6 USB A connection Allows an external FAT32 drive to export measurement data from past 30 days 7 Push button Allows to export measurement dat...

Page 9: ...and remote report server Ethernet connection is disabled is first release firmware Check www dateq nl for firmware update and current available futures 13 Power Power connection 24 volt advised 1 amp 24 Watt Normal operation 0 5 amp 12 Watt 14 USB USB A connection for data dump on external FAT32 drive 15 Control button Control button for dump of 30 day measurement data on external FAT32 drive Futu...

Page 10: ... for wall mount M4 max length 12mm 18 Standard Standard mounting bracket provided with the SPL D3 M4 max length 12mm Standard mounting bracket for M10 G hook mounting M4 max length 12mm 19 Safety mount M5 DIN screw for mounting an extra safety cable Max screw length 12mm ...

Page 11: ...g specifications IEC 61672 1 class 2 France Measurement chain designed to comply according specifications NFS 31 122 1 2017 and decrét 2017 1244 BE Measurement chain designed to comply according specifications VLAREM II Cat 1 Cat 2 and Cat 3 DE Measurement chain designed to comply according specifications DIN 61672 DIN 60651 and DIN15905 5 Power supply Supply voltage 24 volt Power usage max 24 Wat...

Page 12: ......

Page 13: ...SPL D3 Multi Color Display Sound level logger Configuration ...

Page 14: ...Notes ...

Page 15: ... Technical specifications 13 Inputs 13 Common 13 Introduction configuration 19 Installation 20 Configuration 20 Configuration license 21 Unlocking the limiter 21 Live 22 Display configuration 23 Microphone 24 Illumination 24 Time slots 24 Circuit breaker 24 Calibration 25 System 25 History 26 Product support 29 ...

Page 16: ...iew settings and logging To adjust configuration settings an additional password and license file is required To connect to the SPL D3 a windows computer with USB support is required The SPL D3 uses a measurement microphone to determine the actual sound level When measurement shows the sound levels are about to exceed the display will change from green to orange and red when levels are actually ex...

Page 17: ...e found at www dateq nl Configuration In this chapter the configuration and system settings for the SPL D3 are explained These settings normally are made once on installation All made settings can be stored in a backup file for later use or restoring the original settings after changing Connecting the computer The computer is connected to the display using a a standard USB A to USB B cable After c...

Page 18: ...closest supplier can be found at the Dateq selling points part of the website www dateq nl An installer license is linked and registered to the installing company and can not be transferred to third parties The installer license contains all company and contact details that will be stored into the SPL limiter during configuration Unlocking the limiter Before changes can be made the license passwor...

Page 19: ...UK DATEQ SPL D3 manual Installation 19 Live The live view of the software allows to monitor the SPL D3 current measurements These displays follow in color of the actual display in green orange and red ...

Page 20: ...ght filter Unweighted Flat filter Z Response times Fast 125mS Slow 1000mS Leq 1000mS 60 minutes Colors Green 30 110dB Orange 70 130dB Red 70 130dB Note the minimum and maximum settings of the color change follow on green orange and orange red threshold VU meter The VU meter shows the actual dB value unweighted Z in Fast response time 125mS The green orange and red threshold points can be set in Gr...

Page 21: ...time and date are set manually by synchronizing the display time to the connected computer time Circuit breaker The SRL1 circuit breaker can be linked to SPL D3 to act as a warning or cut power on overshooting the maximum set dB level The source of the dB value can be selected to one of the three displays Sanction level shows the maximum level corresponding with the orange red threshold setting Th...

Page 22: ... When a valid firmware is found the display will show E3 bootloader mode on the large display and update the firmware Note Some windows builds do not fully support the bootloader mode When the progress bar does not start and the display is in E3 disconnect the USB cable and reconnect it again The update starts running after reconnecting Settings Save settings allows a backup of the current device ...

Page 23: ...ctive unit that can only be restored at the Dateq service desk Select date Select the date that needs to be inspected Display Graph Select the checkbox of measurement value s that needs to be displayed Zoom Use the scroll wheel of your mouse to zoom in and out of selected measurement areas Print Print the current graphic view including zoom to your printer Export Export all measurement data from t...

Page 24: ...24 Installation DATEQ SPL D3 manual UK ...

Page 25: ...UK DATEQ SPL D3 manual Installation 25 ...

Page 26: ...Product support For questions about the SPL series limiters accessories or other products contact Dateq at Dateq Audio Technologies B V De Paal 37 Phone 036 54 72 222 1351 JG Almere E mail info dateq nl The Netherlands Internet www dateq nl ...

Reviews: