4.7 FAN ROTATION INSPECTION
Fan motor rotation should be inspected. CS compressors uses an axial fan for cooling. Fan
rotation is inspected through an arrow shaped observation hole above the fan motor. The
fan must rotate in the direction indicated by the arrow.
NOTICE!
Always inspect fan rotation through the observation hole. Never assume the fan
rotation is correct based on the induced air flow across the coolers. A centrifugal
fan can pull the airflow across the coolers when rotating in either direction;
however, incorrect rotation will cause high discharge temperature.
Operation
5.1 ROUTINE OPERATION
Provisions should be made to have the instruction manual readily available to the
operator and maintenance personnel. If, for any reason, any parts of the manual
become illegible or if the manual is lost, have it replaced immediately. The
instruction manual should be read periodically to refresh one’s memory. This
may prevent a serious accident.
Before compressor start up, inspect fluid level in reservoir. After start up, observe the
control panel screen for operation status. Ensure the compressor is running at its optimum
level.
Close the service valve to plant air distribution system. Allow pressure to build up within
the reservoir until compressor fully unloads. Press the stop button.
Always close the service valve when compressor is not being used. It prevents
back pressure from the service line and avoids leakage due to check valve failure.