31
LOWER VOLTAGE
****V
Controller detects the voltage lower
than the set value, the shutdown
protection, reported voltage is too low.
Set this value to 0000, the low voltage
function is no function
LOW T PROTECT
-48
℃
Controller detects the temperature is
lower than this value, display
temperature is too low, not allowed to
start the air compressor
MAX RUN TIME
0000H
When the compressor run time is
greater than TIME LIM set, the
controller will stop the compressor
and alarm ;If the value set as
‘0000’the function is disable.
ALARM LONG STOP
0010H
Warning time over here to set,
compressor report "warning too long"
and stop
COM SET PAR.
DISABLE/ENABLE
PARAMETER 1
****
Operation
Functions and Technical Parameters
1. Digital input: Digital input of 3# circuit; digital output of relay of 5# circuit;
2. Simulation quantity: Pt100 temperature input of 1# circuit; 4
~
20mA input of
transducer of 1# circuit; two groups of three phase current input(CT provided
);
3. Input voltage of phase sequence: three phase 380V/220V
;
4. Controller’s power supply: AC20V,50Hz,10VA
;
5. Measurement range displayed:
a
)
Oil temperature:-50
~
150
℃
; precision: ±1
℃
.