Chapter 2 Installation Introductions
1.
Using included key unlock drive carrier, push the leveler to right and lift it up to release the handle, and then withdraw
the drive carrier.
2.
Set the jumpers of all the drives to the mode of “
Master or Slave”
When RM12_1394B is in RAID0 mode, we recommend using identical hard drives but mixed types and sizes will also
work.
3.
Connect the power and IDE connectors with the drive; fasten the drive with four screws (Please keep the space
between the drive and the temperature sensor).
4.
Put the drive carrier back to the chassis; push the handle back to lock the drive carrier.
5.
Install the 1394B card of the accessory in your computer; use the 1394B cable (included) to connect 394B port with the
1394 card. There are two 1394B ports and one 1394A in the 1394 card
6.
1394B port offer transfer rate at 800mbps where 1394A offer transfer rate at 400mbps, we recommend to use 1394B
port instead of 1394A
7.
Daisy chain ability, we can
Chapter 3 System Starting
3.1 Indicators and Switch
3.1.1 LED Indicators Power LED (Green): Always on
Data Access LED (Yellow): Flashing when data’s writing or reading
3.1.2 Alarm Indicators
Temperature Monitoring:
This indicator stays green when the operating temperature inside the chassis is normal (under 105°F). It will turn red when it
is over the normal operating temperature.
Fan Monitoring:
When the fans operate normally, this indicator stays green. It will turn red when one of the fans malfunction or stop working.
POWER LED Data Access LED
3.1.3 Switch
3.1.3.1 SW: Alarm Reset
The alarm will go off when the operating temperature is above limit or one of the fans stop running. You may select to stop
the alarm by pressing the SW and have the system running continually (NOT RECOMMENDED).