Operation
PSM-500/500L/500LT SCPC Satellite Modem
Page 3-16
PSM-500/500L/500LT - Rev. 0.91
Table 3-6. Modulator Parameter Detail
Modulator Parameter Detail
Representation
Type
Entry
Description
Status CXR
Sending, OK
Read Only Read Only
Modulator Carrier Status
Status Data
NO DATA
Read Only Read Only
Modulator Input Data Status
Status Clock
Internal, OK
Read Only Read Only
Modulator Bit Rate Clock
Status
Status Test
Normal
Read Only Read Only
Modulator Test Status
IF Frequency
70.000000MHz
Numeric
50.000 000 to 90.000 000
MHz
Carrier center frequency
IF Offset
–8.031kHz
Numeric
–1,250.000 to +1,250.000
kHz
Carrier offset frequency
IF Level
–20.4dBm
Numeric
+5.0 to –35.0 dBm
+3.0 max at 50
Ω
Transmit output power level
IF Output
Enabled
Selection
0 = Disable, 1 = Enable
Carrier output enable
IF Modulation
QPSK
Selection
0 = BPSK, 1 = QPSK,
2 = OQPSK, 3 = 8PSK,
6 = 16QAM
Modulation Mode. Some
values left available for new
options.
IF Spectrum
Normal
Selection
0 = Normal, 1 = Inverted
Modulation Spectrum control
IF Filter Mask
Normal
Selection
0 = IESS, 1 = Legacy
Modulation Spectrum Filter
Control. Legacy for PSM-
4900 compatibility.
»IF Mode
Continuous
Selection
0 = Continuous, 1 = Burst
Only available with burst
option installed.
»IF Preamble
64 Symbols
Selection
0 = 32, 1 = 64 Symbols
Selects preamble length when
burst option installed.
IF AUPC
Disabled
Selection
0 = Disable, 1 = Enable
Automatic Uplink Power
Control
»IF AUPC Eb/No
6.5dB
Numeric
3.0 to 20.0 dB
AUPC remote receive Eb/No
level set point.
»IF AUPC Max Lvl
–10.0 dB
Numeric
+5.0 dBm to Minimum level
Max. Transmit level under
AUPC control
»IF AUPC Min Lvl
–20.0 dB
Numeric
Maximum level to –35 dBm
Min. Transmit Level under
AUPC control
IF Mute
Manual
Selection
0 = Automatic,
1 = Confirm,
2 = Manual
3 = Manual & Pwr Loss
Manual requires manual
Carrier enable after Mod
output change. Option 3
forces Cxr off after power fail.
IF Impedance
75 Ohm
Selection
0 = 50
Ω
, 1 = 75
Ω
Transmit IF impedance.