CROSSLINE LASER LEVEL

TABLE OF CONTENT

SPECIFICATIONS  ........................................................................................................3
HAZARD SIGNAL WORD DEFINITIONS .................................................................3
GENERAL SAFETY RULES FOR OPERATION .........................................................4
COMPONENT IDENTIFICATION ...............................................................................5
OPERATION INSTRUCTION ......................................................................................6
CALIBRATION CHECK ................................................................................................7
MAINTENANCE AND SERVICE .................................................................................9
TROUBLESHOOTING .................................................................................................9
PRODUCT LABELS  .....................................................................................................10
WARRANTY INFORMATION .....................................................................................12

Summary of Contents for DT1H1V2PG

Page 1: ...CROSSLINE LASER LEVEL WITH PLUMB DOTS MODEL NO DT1H1V2PR DT1H1V2PG OPERATING INSTRUCTIONS TOPREVENT SERIOUS INJURY READ AND UNDERSTAND ALLWARNINGS AND INSTRUCTIONS BEFORE USE ...

Page 2: ...SPECIFICATIONS 3 HAZARD SIGNAL WORD DEFINITIONS 3 GENERAL SAFETY RULES FOR OPERATION 4 COMPONENT IDENTIFICATION 5 OPERATION INSTRUCTION 6 CALIBRATION CHECK 7 MAINTENANCE AND SERVICE 9 TROUBLESHOOTING 9 PRODUCT LABELS 10 WARRANTY INFORMATION 12 ...

Page 3: ...nal Part No DT01REC sold seperately DATUM is constantly improving its products All information in this manual is based on the latest product information available at the time of printing The specifications outlined herein are subject to change without prior notice or obligation The purchaser and or user shall assume liability for any modification and or alterations of this equipment from original ...

Page 4: ... eyes Set up cross line laser to ensure laser beam path is above or below eye level Ensure cross line laser is securely set up to avoid accidental movement Always ensure the laser beam is aimed at a sturdy work piece without reflective surface Bright shiny reflective sheet steel or the like is not suitable for laser use as the reflective surface could direct the beam back at the operator Do not br...

Page 5: ...window 4 Up plumb dot output window 5 Horizontal laser output window 6 1 4 Tripod thread 7 Down plumb dot output window 8 Battery compartment 9 Wall bracket 10 Magnets on b 11 Height adjustment knob 12 1 4 thread 13 Down plumb dot window 14 5 8 Tripod thread 15 1 4 Tripod thread 2 5 1 3 4 6 7 8 9 11 14 10 13 15 12 ...

Page 6: ...switch is turned to OFF position LASER LINES SELECTION Turn the switch to ON position All lines appear when the laser is turned on Press LINE button to select laser lines AUTOMATIC SELF LEVELLING Pendulum lock power switch to ON position must be released for horizontal and vertical levelling Turn on the laser level The pendulum automatically aligns a position within the range of self levelling ran...

Page 7: ...rt The best calibration results can be achieved if the laser is mounted on a tripod 1 Mark point A1 on the wall 2 Turn the device 180 and mark A2 on the opposite side of A1 You now have a horizontal reference between point A1 and A2 3 Position the device as near as possible to the wall at the same height of point A1 4 Turn the device 180 and mark point A3 The difference between point A2 and A3 is ...

Page 8: ...cal laser to the plumb line The precision is within the specified tolerance if the deviation between the laser line and the plumb line is not greater than 2mm CHECKING THE HORIZONTAL LINE 1 Position the device about 5m from a wall and switch on the cross laser Mark point B on the wall 2 Turn the laser cross approx 2 5 m to the right and mark point C 3 Check whether the horizontal line from point C...

Page 9: ...g temperature moisture can form inside where it may damage circuit board Avoid shock vibrations and extreme heat Do not immerse the instrument in water Always slide the power switch to the OFF position when storing transporting or moving around the job site Calibration service is recommended at least once a year or as needed TROUBLESHOOTING ISSUE POSSIBLE CAUSE AND SOLUTIONS Laser does not turn on...

Page 10: ...l with Plum Dots Red DT1H1V2PR Date 02 07 2019 Nicole Jim Dieline Pantone 166 C Brand DATUM Description CROSS LINE LASER LEVEL WITH PLUMB DOTS RED BEAM Pronto 135040 Part DT1H1V2PR Barcode 9328225049279 Country of Origin CHN Supplier 000SUZHFUK Sup EK118DT 2P RED Contact Steven Email steven fukudalaser com CAUTION LASER RADIATION DO NOT STARE INTO BEAM ACCORDING TO IEC EN 60825 1 2014 MADE IN CHIN...

Page 11: ...11 OPERATING MANUAL ...

Page 12: ... product Consumer guarantees Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a m...