G 3
recessed
Noises
Software Failure / Loss of Dashboard Control
Notes about the pulse alarm
ergo_lyps
ergometers are equipped with quality ball bearings and a silent belt drive. However, it cannot
be avoided that remaining noises be heard, which are in the range of LpA 52 dB (decibel).
All computer controlled appliances have one undesirable
characteristic in common that is that the normal software
operation can sometime fail for generally unknown reasons.
This situation is generally described by the expression
“the system has frozen”
. Should the dashboard operation
fail and cannot be restored by mean of normal keys functions,
then the solution would be to press the recessed
RESET key (No. 18) underneath the dashboard with
a pointed tool (e.g. a pencil or ball pen).
The squeaking or other disturbing noises generally originate from:
- Loosening of the crank arm fastening screws! (See also page G4)
- The bearings of the oscillating poles.
- The fastening screws of the feet or dashboard support column!
- Wear of the V-belt
- Wear of the slipping coupling
- Wear of the bearings
These screws must be tightened every 500 km!!
If you enter the age of the user under
“Age”
, and a pulse limit value that should not be exceeded under
“pulse higher limit”
in the
“Data entry and alarm levels set up”
mode (see pages 14 to 17), then
the alarm will always sound whenever
- the aerobic zone corresponding to the age of the user is exceeded
(see page 7)
and
- the value entered under
“pulse higher limit”
is reached (see pages 14 to 17)
If you want the alarm to sound only when the pulse limit value entered
under “pulse higher limit” is reached, you should enter zero as the user age under “Age”!!
Drive / Braking unit
(eddy current brake)
If a major failure is detected on the
drive unit
, it is possible to replace the complete unit. The braking unit,
which consists of the flywheel, a transformer, a belt tensioning device and the mounting plate, is mounted
with only three screws.
You can order an exchange unit from
daum electronic GmbH
. The defective unit can then be relatively
easily replaced with the new one, without requiring any adjustment, by your dealer or a bike mechanic.
.
The flywheel of the
ergo_lyps
is equipped with two journal bearings. These bearings continue to run
for a little while after you stop pedaling. Feeling a light drag on the foot rods is then normal. The journal
bearings should be lubricated with Klüberplex BEM 34-132 grease every about 3000km (if the drag on
the foot rods increases and becomes uncomfortable), depending on the load.
or also
Please note that all the personal data,
and all training data and results will
be definitively lost when you press
the RESET key!!
RESET key
General Recommendations
What to do, if ...?