LOCK USERS FUNCTIONS
All locks are shipped from the factory in pre-setup mode,
with no features installed.
EXIT PRE-SETUP
KEYPAD SETUP
MASTER FUNCTIONS
LOCKS
ENTRY DEVICE OPTIONS
+
User ID plus 6 digit PIN
+
Time Delay: Delay 01-99; Open 01-19
+
Duress (+/- last digit of combination, if enabled)
+
Single Access Mode - one combination required to open.
+
Dual Access Mode - two combinations required to open
(if enabled.)
+
Wrong Try (4 wrong combinations = 5 minute lock out)
+
If a mistake is made, wait thirty (30) seconds and
repeat operation.
+
Double signal - two (2) LED flashes and two (2) beeps -
indicates entry is valid or accepted.
+
Triple signal - three (3) LED flashes and three (3) beeps -
indicates invalid or not accepted.
Master User - Lock setup, add Users, and Master Reset
Manager User - Open Lock, Enable/Disable Users,
Delete/Reinstate User, set Time Delay, and Audit
Access User - Open Lock
+
User 02 -30
+
User 31 (Time Delay Override, if enabled)
Lock will open when 1 is pressed.
1. Press and hold the “0” key until unit double signals.
2. Enter the default Master Combination, 00 5-5-5-5-5-5.
+ Unit will signal twice.
Lock is now in setup and test mode.
+
ONLY the Master can enroll manager and users!
+
ONLY the manager can select operational modes: Time
Delay Override, Dual Mode, or Silent Alarm. (Special
Function 8, see configuration chart.)
To enroll/activate the Manager (Master only)
To enroll/activate Users (Master only)
4300
Dual-Handed
Swing bolt
6040
Dead bolt
3125
Round Entry
8130
(Optional)
NOTE: User IDs are underlined in the instruction
for identification purposes.
NOTE: Perform all Administrative Functions with the door open.
NOTE: User 31 must be activated to use Time Delay Override.
NOTE: the Manager can open the lock, but all other “Manager
Function” will not be available until the Lock is in Operational
Mode (see Exiting Setup Mode.)
NOTE: Each combination must be changed independently at the
Lock. When selecting a combination, do not use a birthday or
other predictable information that could give correlation between
the user and the combination.
1. Enter Master combination (00 555555) and hold down last digit
of combination until unit double signals and the LED stays on.
2. PRESS 1 (add user).
3. Enter Manager ID 01; lock should beep twice and LED stays on
4. Enter the Manager ID 01 and combination XXXXXX. (Example:
01 123456)
5. Re-enter 01 XXXXXX
6. The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Key press sequence – 00 555555(hold last) 1, 01, 01 123456, 01
123456
Manager is now enrolled and activate; to test enter the Manager
ID and combination; the lock should open.
1. Enter Master combination (00 55555) and hold down last digit
of combination until unit double signals and the LED stays on.
2. PRESS 1 (add user).
3. Enter User ID (02-31); lock should beep twice and LED stays on.
4. Enter User ID and combination XXXXXX (example: 02 222222).
5. Re-enter ID XXXXXX
6. The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Repeat the process for each User enrolled.