Supra v1.10

MASTER SETUP AND OPERATIONAL INSTRUCTIONS

LOCK OPERATING CONVENTIONS:

LOCK USERS FUNCTIONS

All locks are shipped from the factory in pre-setup mode,
with no features installed.

EXIT PRE-SETUP

KEYPAD SETUP
MASTER FUNCTIONS

LOCKS

ENTRY DEVICE OPTIONS

 

+

User ID plus 6 digit PIN

 

+

Time Delay: Delay 01-99; Open 01-19

 

+

Duress (+/- last digit of combination, if enabled)

 

+

Single Access Mode - one combination required to open. 

 

+

Dual Access Mode - two combinations required to open 

      (if enabled.)

 

+

Wrong Try (4 wrong combinations = 5 minute lock out)

 

+

If a mistake is made, wait thirty (30) seconds and  

      repeat operation.

 

+

Double signal - two (2) LED flashes and two (2) beeps - 

      indicates entry is valid or accepted.

 

+

Triple signal - three (3) LED flashes and three (3) beeps -     

      indicates invalid or not accepted.

Master User - Lock setup, add Users, and Master Reset

Manager User - Open Lock, Enable/Disable Users,

Delete/Reinstate User, set Time Delay, and Audit

Access User - Open Lock

 

+

User 02 -30

 

+

User 31 (Time Delay Override, if enabled)

Lock will open when 1 is pressed.

1.  Press and hold the “0” key until unit double signals.

2.  Enter the default Master Combination, 00 5-5-5-5-5-5.

+ Unit will signal twice.

Lock is now in setup and test mode.

 

+

ONLY the Master can enroll manager and users!

 

+

ONLY the manager can select operational modes: Time 

Delay Override, Dual Mode, or Silent Alarm. (Special 

Function 8, see configuration chart.)

To enroll/activate the Manager (Master only)

To enroll/activate Users (Master only)

4300

Dual-Handed

Swing bolt

6040

Dead bolt

3125

Round Entry

8130

(Optional)

NOTE: User IDs are underlined in the instruction 

for identification purposes.

NOTE: Perform all Administrative Functions with the door open.

NOTE: User 31 must be activated to use Time Delay Override.

NOTE: the Manager can open the lock, but all other “Manager

Function” will not be available until the Lock is in Operational

Mode (see Exiting Setup Mode.)

NOTE: Each combination must be changed independently at the

Lock. When selecting a combination, do not use a birthday or

other predictable information that could give correlation between

the user and the combination.

1.  Enter Master combination (00 555555) and hold down last digit 

of combination until unit double signals and the LED stays on.

2.  PRESS 1 (add user).

3.  Enter Manager ID 01; lock should beep twice and LED stays on

4.  Enter the Manager ID 01 and combination XXXXXX. (Example: 

01 123456)

5.  Re-enter 01 XXXXXX 

6.  The Lock will double signal if the operation was successful, and 

triple signal if not accepted.

Key press sequence – 00 555555(hold last) 1, 01, 01 123456, 01

123456

Manager is now enrolled and activate; to test enter the Manager

ID and combination; the lock should open.

1.  Enter Master combination (00 55555) and hold down last digit 

of combination until unit double signals and the LED stays on.

2.  PRESS 1 (add user).

3.  Enter User ID (02-31); lock should beep twice and LED stays on.

4.  Enter User ID and combination XXXXXX (example: 02 222222).

5.  Re-enter ID XXXXXX

6.  The Lock will double signal if the operation was successful, and 

triple signal if not accepted.

Repeat the process for each User enrolled.