background image

V1.0_0212 |   Division of Davcor Group Pty Ltd     |     www.smartlock.com.au     |     www.smartlock.co.nz

1.  Plug Interface into PC and open LGViewer software on PC.

2.  Connect Interface to front of keypad and click safe icon button 

on the PC software to begin acquisition.

3.  Enter Manager combination and 

hold down last digit of 

combination until unit double signals and the LED stays on.

4.  PRESS 7. Unit signals once and Audit will be sent.

5.  Disconnect Interface Cable from PC and keypad.

1.  Must add at least one (1) user to open lock.  

(See Enroll Activate Users.) 

• At least one user must be active; all users cannot be disabled 

or deleted.

2.  If Time Delay is active, one valid combination will start Delay 

period. 

• Two combinations required to open lock in Open period.

66E

Supra v1.10

Time Delay – Lock Response

Time Delay Override

 (If feature is enabled)

Silent Alarm 

(If feature is enabled AND optional Alarm Box is 

connected to an alarm system)

Disable Lock 

(Optional Alarm Box is connected to an alarm system)

Wrong Try Penalty

Dual Access Mode

 (If feature is enabled)

Receive Audit

(Manager Only; this function requires Serial Interface [P/N 43087] 
and LGViewer Software)

 

+

During the Delay Period the LED will flash every second.

 

+

During the Open Period the LED will flash twice a second, and    

the Entry Device will beep every 10 seconds.

 

+

Repeated LED flashing beeping after an opening indicates 

that the battery is low and needs immediate replacement. It is 

recommended that batteries be replaced at least once a year.

 

+

Uses alkaline battery only. (Example: Duracell™ or Eveready™ 

alkaline batteries.)

 

+

When the battery level becomes too low to safely operate 

the lock any key press will give a low battery warning, and the 

battery must be changed before the lock will operate.

If battery is depleted and will not allow lock to open, follow 

instructions found in the User Instructions for your keypad. 

Lock contains a non-volatile memory; even with batteries 

removed the lock will retain all programming.

 

+

Must add User 31. 

(See Enroll/Activate Users.) 

- If User 31 is disabled or deleted, this feature will no longer 

function.

 

+

Entry of Override combination during Delay period will open 

the lock.

Enter last digit of combination one number higher or one number 

lower.

Example: Combination: 01 1-2-3-4-5-6

Duress: 01 1-2-3-4-5-5 or 01 1-2-3-4-5-7

The lock will open without any indication that the duress signal has 

been sent.

Alarm Box (2789 or 4002) required. Input signal to the Alarm Box 

will disable the lock opening by a valid combination.

Entry of four (4) consecutive invalid combinations starts a five (5) 

minute delay period.

- LED flashes red at ten (10) second intervals.

At the end of the delay period, two more consecutive invalid 

combinations will start the five (5) minute delay period.

During delay period keystrokes will respond with three 

signals.

Battery Low Warning

Reviews: