71
OB-6 Operation Manual
Appendix C: MIDI Implementation
Appendix C: MIDI Implementation
The OB-6 receives MIDI data according to the settings you have chosen
in the
global
settings. In addition, there is interaction between some of
the Program parameters that determine the overall response of OB-6 to
MIDI data. Following are the Global parameters that affect response to
MIDI:
MIDI Channel:
All
,
1
…
16
—
Selects which MIDI channel to send and
receive data, 1 to 16. All receives on all 16 channels.
MIDI Clock:
Sets the OB-6’s ability to send and receive MIDI clock
messages:
•
Off
: MIDI Clock is neither sent nor received
•
Out
: MIDI Clock is sent, but not received
•
In
: MIDI Clock is received, but not sent
• Slave Thru (
i-0
): MIDI Clock is received and passed to MIDI Out
• In, No Start/Stop (
n55
): Receives MIDI Clock but does not respond to
MIDI Start or Stop command.
When set to
in
or
slave
thru
, if no MIDI clock is present at the selected input,
the arpeggiator and sequencer will not function.
Clock Port:
MID
,
USB
—
Sets the port(s), MIDI or USB, by which MIDI
clock signals are received.
Param Xmit:
Off
,
CC
,
NR
—
Changes to the values of front panel controls
are transmitted via MIDI as Continuous Controllers (
CC
) or Non-registered
Parameter Number (
NR
). Transmission of parameters can also be turned off.
NRPNs are the preferred method of parameter transmission, since they cover
the complete range of all parameters, while CCs are limited to a range of 128.
Param Rcv:
Off
,
CC
,
NR
—
Sets the method by which parameter changes are
received via MIDI. As with transmission, NRPNs are the preferred method.
Summary of Contents for ob-6
Page 1: ...Operation Manual...
Page 2: ......
Page 10: ......
Page 94: ...84 Appendix C MIDI Implementation Dave Smith Instruments...
Page 95: ......