background image

 

 

 

17 

 

7. Accuracy Checking 

Follow these instructions for checking axis accuracy. 

7.1 Horizontal-surface Checking 

 

1.  Place  the  instrument  at  the  point  of  50m  in  front  of  wall  (or  set  a  scale  plate  at  the  point  of  50m  away  from  the 

instrument),  and  then  adjust  the level  of  the  base  approximately  to  aim  the  X1  to  the  wall  (or  scale  plate),  as  depicted 

below:

 

                             

         

 

Summary of Contents for RL250S

Page 1: ...0 Automatic Self leveling Rotary Laser RL250S User Manual...

Page 2: ...securely fixed The tripod leg clamps should be securely fastened If not securely fastened or tightened the main unit could fall off or the tripod could fall over The laser should not be stored or used...

Page 3: ...2 1 What is included with your RL250S...

Page 4: ...Main Instrument Detector and Bracket Remote Control Charger Target Glasses Hard Case with Foam Insert Extra Alkaline Battery Pack c w 4xAAAlkaline batteries Wall Mount Bracket Please contact your supp...

Page 5: ...4 2 Handle Optical Glass Light House Control Panel Base Rotating Head Plug Hole Plumb Up Beam Plumb Down Beam Find your way around the RL250S...

Page 6: ...5 2 1 Control Panel Switch ON OFF Left Spin Right Spin Direction Scan Arrow Area Manual Auto H I Alert Head Speed...

Page 7: ...be set up by two arrows on panel In these period the other functions such as scanning left spin or right spin are also available but without accuracy When press Manual Auto the third time the laser w...

Page 8: ...includes 5 levels 0 10 45 90 180 H1 is without this function 9 Left spinning Allows the laser beam to step move counter clockwise only when the unit is in 0 RPM or scan mode H1 is without this functio...

Page 9: ...battery pack according to the right electrode 3 Re screw the bolt at the bottom of base part 4 H1 comes without Ni Mh battery pack 3 2 Instrument Placement 3 2 1 Horizontal scanning Place the instrume...

Page 10: ...g head will rotate at the speed of 600 RPM If the instrument is placed improperly or the slope of instrument exceeds the range of 5 to 5 the mode indicator and the laser beam will blink at the same ti...

Page 11: ...r module will scan directionally If press the key repeatedly the angle of scanning of laser module will continuously change as follows 0 10 45 90 180 0 2 Press the Key Left spinning or the Key Right s...

Page 12: ...he Y1 beam to the direction of the slope required b Press the arrowor to move the laser beam up or down until the beam line get to its required position 3 Quit slope adjustment mode Press Manual Autom...

Page 13: ...12 3 3 6 Vertical Lines Once the instrument is in the position shown above The instrument will Auto level and start spinning giving a Vertical beam...

Page 14: ...13 4 Power Plug Hole Alkaline Battery Pack...

Page 15: ...Mh battery pack the standard one or Alkaline battery pack is available to work as power supply Notices 1 Using the standard rechargeable batteries of the instrument recharging will be finished within...

Page 16: ...on Available distance indoor 30M outdoor 20M The keypad panel includes 9 keys the indicator on the RC will wink to show the operating signal has been sent out once pressing any key Functions fulfilled...

Page 17: ...is will either give a narrow or a broader range of detection When the detector is too high a slower beep will be emitted when too low a fast beep will be emitted when same level as beam a continuous p...

Page 18: ...acy 7 1 Horizontal surface Checking 1 Place the instrument at the point of 50m in front of wall or set a scale plate at the point of 50m away from the instrument and then adjust the level of the base...

Page 19: ...e mark the beam position on the wall or scale plate as H2 The difference between the value of H1 and H2 should be less than 10 mm 4 Repeat the same process to check your Y axis beam Again the differen...

Page 20: ...rizontal line checking First lay down the instrument Mount the instrument on tripod between A wall and B wall Tripod near Wall A Distance should follow the instructions on illustration Switch the inst...

Page 21: ...wall A Mark the centre point of the laser beam on the wall Point I Turn the instrument horizontally by 180 without changing the height after leveling direct the laser beam onto Wall B Mark the centre...

Page 22: ...tripod Switch on the instrument and let it leveling After leveling align the height of the instrument by using tripod or by underlaying if necessary In such a manner that the centre point of the laser...

Page 23: ...d mark the centre point of the laser beam on wall A point III Tare care that point III is as vertical as possible above or below point I The difference D of both marked points I and III on wall A amou...

Page 24: ...90 180 Bright visible beam Wavelength 635nm HV Class II Wavelength 535nm HV Green Class 3R IR Remote control Available distance 20 m Operation temperature 20 C 50 C 4 F 122 F Power supply DC 4 8 6V 4x...

Reviews: