Electrical Power Surge Protection

An electrical power surge or spike can travel on the supply lines and cause serious

damage to your electrical equipment. The Steriflo

®

control box has a 1 Amp fuse

to protect the circuit. The fuse is not a lightning arrestor and may not protect the

Steriflo

®

if lightning or a very powerful surge hits the unit.

If the installation is subject to electrical power surges or lightning we strongly

recommend the use of suitable additional surge protection devices on ALL

electrical equipment.

We recommend the use of an RCD or earth leakage circuit breaker

on the

power supply to your unit.

Pipe Connections

Never use PVC pipe directly connected to unit. PVC pipe and fittings can be used

after 90

o

metal elbows are connected to the inlet and outlet of the chamber eg.

brass fittings. Larger diameter pipe may be used to minimise resistance to flow,

but maximum flow rates should not be exceeded, as correct water treatment

cannot be assured at higher flows. If flows may exceed the design maximum,

install a flow restriction device.

Use unions at pipe connections to enable easy removal and servicing. Use

sufficient tape to ensure airtight seal and do not over tighten. To prevent strain on

unit threads always support heavy inlet and outlet pipes.

Pre-treatment (drinking water)

Prefiltration is usually required to ensure that particulate matter does not shield

micro-organisms from the UV light. Sand filtration or 20 micron cartridge filtration

is the usual minimum. To protect against cysts such as Giardia or

Cryptosporidium, secondary depth cartridge filtration is recommended - a least 5

micron, but preferably 1 micron. Whole supply of depth cartridge filtration is

recommended however is some cases installing on the drinking supply may only

be practical.

Do not use pipe thread sealing compounds (especially hemp) on

any part of this unit. ONLY use Teflon sealing tape.

NOTE: Prior to installation remove the transport plugs from the

inlet, outlet and lamp end cap.

DO NOT DISASSEMBLE ANY COMPONENTS UNTIL YOU HAVE

FULLY READ THESE INSTRUCTIONS!

Ultra violet radiation is harmful to skin & eyes.

DO NOT LOOK AT UV LAMP WHILE LAMP IS OPERATING.

Summary of Contents for Steriflo UV50

Page 1: ...Maximum operating pressure for stainless steel UV chambers is 860kPa 125 psi If this pressure can be exceeded or if operating close to this pressure fit a suitable pressure limiting valve in the supply to the UV chamber If any electrical supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not i...

Page 2: ...on Page 5 Electrical Power Surge Protection Page 5 6 Pipe Connections Page 6 Pre treatment drinking water Page 6 Lamp Installation Page 7 Operation Page 7 Maintenance Page 8 9 Water Quality Page 9 Lamp Fail Alarm Page 9 Trouble Shooting Page 10 Specifications Page 10 Spare Parts Page 10 Warning UV Radiation Page 11 After Sales Service Page 11 ...

Page 3: ...uctions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Ultra Violet water treatment system is designed to handle clean water free of particulate matter The system should not be used for any other purpose without specific referral to Davey Water Products The use of the system with flammable corrosive and other materials of a hazardous natur...

Page 4: ...uring servicing Leave a chamber lengths space at the lamp connector end for lamp removal Installation can be horizontal outlet facing upwards or vertical outlet horizontal Housing your Steriflo System To protect your Steriflo system from the weather make sure the site is water proof frost free and has adequate ventilation Allow for drainage to avoid damage to flooring etc that over time may occur ...

Page 5: ... only work when unit is connected to the correct electrical supply Install the power supply enclosure above the treatment chamber so that in the event of a leak water cannot drip down the lamp lead into the enclosure CAUTION The supply cord is necessary for lamp changing The three pin supply plug must remain accessible after installation If installed to fixed wiring without the plug a two pole swi...

Page 6: ...lows If flows may exceed the design maximum install a flow restriction device Use unions at pipe connections to enable easy removal and servicing Use sufficient tape to ensure airtight seal and do not over tighten To prevent strain on unit threads always support heavy inlet and outlet pipes Pre treatment drinking water Prefiltration is usually required to ensure that particulate matter does not sh...

Page 7: ...ith the screws provided Operation Once all leak testing and lamp fitment has been completed prime pump and connect pump lead to supplied outlet Connect three pin plug to power outlet and switch on Open valves and allow water to fill the chamber The Mains On Amber LED will be illuminated and the red alarm light will flash slowly Note If chamber does not fill with water within two minutes reprime th...

Page 8: ...ir the UV output The quartz sleeve should be removed after one month and inspected for deposits Clean with methylated spirits 5 hydrochloric acid if heavily fouled and carefully dry Handle the sleeve with tissue to keep it clean The sleeve should be cleaned every three months or as required Sleeve removal use care fragile 1 Remove lamp as described 2 Remove drain port cap and empty water from cham...

Page 9: ...replaced as required to maintain them in good condition UV transmissibility UVT of the water can be tested by your local dealer or by undertaking an appropriate water test Lamp Alarm System If the UV lamp is out due to a failure or bad connection the alarm buzzer will sound and the flashing red LED will light continuously The alarm will disconnect power to the pump lead preventing untreated water ...

Page 10: ... short in lamp circuit Specifications Flow range UV50 0 50 l min Flow range UV70 0 70 l min Water temperature range 8 35o C Water pressure 0 860 kPa Operating voltage frequency 220 240v 50Hz Power consumption 45 W Lamp life 9 000 hours 1 year s running Spare Parts Lamp GPH550N2W Sleeve TT600 End nut S333A Cover plate S334A Lamp connector and lead S486 Oring S24x3N70 White pressure ring S113 WARNIN...

Page 11: ...l hours later Severe exposure sore red eyes sensitive to light painful to keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attention SKIN In mild cases removal fro...

Page 12: ...islation of the various Australian states or the Consumers Guarantee Act 1993 NZ Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from the product or any defect 7 Where the Trade Practices Act Aust the Goods and Consumer Protection Legislation of the various Australian states and t...

Reviews: