background image

– 3 –

7.  Remove the sand guide and all traces of media from the tank flange.

8.  Ensure the closure o-ring is clean and in the correct position. If necessary, apply 

a thin film of oring lubricant to the o-rings. Assemble the multiport valve to the 

tank aligning the ports to the appropriate plumbing.

9.  Apply Teflon tape to the thread on the pressure gauge and barrel unions and 

screw into the multiport valve body.  7 turns of tape is required.

CAUTION

•   A non return valve is required in between the pump and filter.

•   On installations where the waste line is more than 3 metres below pool 

water level and more than 12 metres in length, a vacuum break valve 

must be fitted in the waste line close to the filter.

•   If an auxiliary pump is installed in line downstream of the filter, it should 

be protected against causing negative pressure in the filter tank.  A flow 

or pressure switch which only enables the auxiliary pump to run when 

the main filter pump is running will achieve this.

•   If the pump and filter are located below pool water level, it is necessary 

to fit isolating valves in the pipe between the pump and the skimmer 

box and in the return pipe from the multiport valve to the pool.  This 

prevents water draining from the pool during maintenance.

FAILURE TO COMPLY WITH THE ABOVE CAUTIONS MAY RESULT IN FILTER 

DAMAGE NOT COVERED BY THE GUARANTEE.

Pipe Connections

Use Teflon tape on all male threads.  Piping should be independently supported and 

not impose heavy loads on the filter or pump.  Use 40mm or 50mm (1

1

/

2

” or 2”) pipe 

from the pump to the skimmer box, return pipe for the multiport valve to the pool and 

from the multiport valve to the drain.

DO NOT OVERTIGHTEN

The fittings and multiport valve on this product are constructed of 

ABS.  Some PVC jointing compounds are incompatible with ABS.  

Check compound suitability before use.

For models that use the 40mm (1.5”) valves, i.e. DCC2140, DCC2540

If the pipe length in the installation, is less than 15m, use the supplied 40mm barrel 

unions as provided with 40mm PVC pipe.
If the pipe length in the installation is greater than 15m, 50mm PVC pipe is 

recommended and the supplied unions should be adapted to suit. 50-40 reducing 

adapters will need to be purchased at your local building/plumbing supplier.

For models that use the 50mm (2”) valves, i.e. DCC2550, DCC2850

 

It is recommended to use 50mm PVC pipe, regardless of the length of the pipe.  

50mm barrel unions are provided with the multiport valve for connection of PVC pipe 

to “pump”, “pool return” and “waste”

NOTE:

Ensure pipework is connected to appropriately labelled multiport 

valve connections.

Summary of Contents for CrystalClear DCC2540

Page 1: ...of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual INSTALLATION AND OPERATING INSTR...

Page 2: ...ble Position the filter tank and pump on a level concrete slab or similar base with minimum dimensions of 900mm x 600mm 3 x 2 Do not use sand to level the concrete slab as it may wash away and cause v...

Page 3: ...nts water draining from the pool during maintenance FAILURE TO COMPLY WITH THE ABOVE CAUTIONS MAY RESULT IN FILTER DAMAGE NOT COVERED BY THE GUARANTEE Pipe Connections Use Teflon tape on all male thre...

Page 4: ...he clean operating pressure of your filter Operating Instructions WARNING FILTER OPERATES UNDER HIGH PRESSURE Ensure all lids closures clamps are correctly secured before operating system Never adjust...

Page 5: ...ge reading as in 2 above it will be necessary to clean or backwash the filter see section on Backwashing the Filter Backwashing the Filter When the filter gauge reading is 40 50kPa above the clean fil...

Page 6: ...uipment This filter is designed to be used with Pool Spa water balanced in accordance with Langlier Saturation Index with a pH level of between 7 2 and 7 6 and is regularly treated with a chlorine san...

Page 7: ...working condition These should be replaced every 3 to 4 years d Remove any obstructions or debris from the main drain cover e Ensure the skimmer baskets and the pump hair and lint pots are free of le...

Page 8: ...which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other l...

Reviews: