background image

INSTALLING YOUR MICROLENE® QUICK CONNECT  

UNDERBENCH SYSTEM

Step One: INSTALLING THE TAP

• 

Determine the most suitable location on your bench top for mounting 

the tap. If your bench top is Marble, Granite or Concrete, do not attempt 

to drill these materials yourself as these surfaces are easily damaged. 

Instead contact your nearest Kitchen Supplier for advice on a trade 

professional to drill the hole for you.

• 

Drill a 13mm (1/2”) hole in your preferred location on the bench top (most 

people prefer a rear corner of the sink). 

• 

Remove the locking nut and washers from the stem of the tap, place the 

tap at the desired angle on the top of the bench and then with a spanner 

firmly connect the locking nut and washers to the stem of tap under 

the bench. The tap should now be fixed to your bench top and held in 

position.

• 

Unscrew the top of the tap and push the spout into place using enough 

force to ensure the orings on the spout are in place. Place the locking 

nut over the spout and screw back into place.

• 

Screw a push lock fitting (female thread) on the threaded end of the tap 

under the bench

Step 2: CONNECTING TO YOUR COLD WATER LINE

• 

Turn off the water supply to the house

• 

Locate the cold water line under the sink. If your cold water line is either 

copper or plastic pipe; you will need to purchase a C-Clamp Kit.  

 

If your cold water line is a flexi hose only use the Pipe Tap Kit.  

Unscrew the flexi hose at the house tap end, screw the main body of the 

pipe tap adaptor into the house tap, and then screw the flexi hose onto 

the threaded end of the pipe tap adaptor.  

 

Screw the smaller outlet tap from the Pipe Tap kit into the female 

threaded port on the main body of pipe tap adaptor. Finally screw a push 

lock fitting onto the male threaded out port of the smaller outlet tap.

WARNING : Microlene

®

 underbench system installation must be in compliance 

with all local legislative requirements. Please note that C-Clamp kit may not be 

accepted in certain markets.

Summary of Contents for microlene

Page 1: ...lene Quick Connect Underbench System Please pass these instructions on to the operator of this equipment WARNING Microlene underbench system installation must be in compliance with all local legislative requirements and installed by a licensed plumber ...

Page 2: ...ene Purifier 1 x Microlene Quick Connect Head with 6 x Screws 1 x C Clamp Kit 1 x Tap 1 x Tap Spout 1 x Pipe Tap Kit 1 x Pressure Limiting Valve 1 x Tubing 2 x Push lock Fittings female thread 2 x Push lock Fittings male thread ...

Page 3: ...enough force to ensure the orings on the spout are in place Place the locking nut over the spout and screw back into place Screw a push lock fitting female thread on the threaded end of the tap under the bench Step 2 CONNECTING TO YOUR COLD WATER LINE Turn off the water supply to the house Locate the cold water line under the sink If your cold water line is either copper or plastic pipe you will n...

Page 4: ...ssure Limiting Valve must be installed in the system before the purifier this is to protect against water hammer or pressure surges from the water supply which could crack the purifier if left unprotected Note Failure to install the Pressure Limiting Valve will void your warranty Cut lengths of tubing to connect the Pipe tap or C Clamp to the Pressure Limiting Valve and the Pressure Limiting Valve...

Page 5: ...t the outlet taps on the Pipe Tap or C Clamp until a flow rate of no more than 4 litres per minute is achieved Using this flow rate it will take 2 minutes and 30 seconds to fill a 10 litre bucket container 1 minute and 15 seconds to fill a 5 litre bucket container or 15 seconds to fill a 1 litre bucket container Check all connections for leaks and tighten connections where required It is recommend...

Page 6: ...Notes ...

Page 7: ......

Page 8: ...gligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorized persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on t...

Reviews: